17
P
OWER
B
LOWER
O
PERATOR
'
S
M
ANUAL
STARTING
WARM
ENGINE
The starting procedure is the same as Cold Start except DO NOT close
the choke.
PB-413H
1.
Throttle Lever
Move throttle lever (A) to IDLE DETENT position.
PB-413T
1.
Throttle Lever/Stop Switch
Move throttle lever (A) forward to idle position. Slide stop switch
(B) forward to run position.
PB-413H, PB-413T
2.
Purge Bulb
Pump purge bulb (D) until fuel is visible and flows freely in the
clear fuel tank return line. Pump bulb an additional 4 or 5 times.
3.
Recoil Starter
Pull recoil starter handle (E) and engine should start. Do not use
choke (C).
NOTE
If engine does not start after 5 pulls, use cold start procedures.
STOPPING
ENGINE
PB-413H
1.
Throttle Lever
Move throttle lever (A) to idle detent position and allow engine to
return to idle before shutting off engine.
2.
Throttle Lever
Move throttle lever (A) to "O" (Stop) position.
PB-413T
1.
Throttle Lever
Release thottle trigger (F). Move throttle lever (A) forward to idle
position and allow engine to return to idle before shutting off
engine.
2.
Stop Switch
Slide stop switch (B) to Stop position.
WARNING
DANGER
If engine does not stop when stop switch is moved to STOP
position, close choke - COLD START position - to stall engine.
Have your ECHO dealer repair stop switch before using blower
again.
A
A
PB-413H
PB-413H
PB-413T
B
A
PB-413T
B
A
F
E
C
D