background image

Power Blower

Operator's Manual

  MODEL      

PB-255

 

 

 

 

 

 

 

 

 

 

 

 

 

X753002695

01/10

X7531180205

    

 

    

   

warning

Read  rules  for  safe operation and instructions  carefully.  ECHO provides this 

Operator's Manual, which must be read and understood for proper and  safe  opera-

tion.

Summary of Contents for PB-255

Page 1: ...r s Manual MODEL PB 255 X753002695 01 10 X7531180205 warning Read rules for safe operation and instructions carefully ECHO provides this Operator s Manual which must be read and understood for proper...

Page 2: ...l or Replacement Manuals 28 Specifications descriptions and illustrative material in this literature are as accurate as known at the time of publica tion but are subject to change without notice Illus...

Page 3: ...y alert symbol accompanied by the word WARNING calls attention to an act or condi tion which CAN lead to serious personal injury or death if not avoided Circle and slash symbol This symbol means the s...

Page 4: ...th cap or net Hot Humid Weather Heavy protective clothing can increase operator fatigue which may lead to heat stroke Schedule heavy work for early morning or late afternoon hours when temperatures ar...

Page 5: ...r operation Repetitive Stress Injuries It is believed that overusing the muscles and tendons of the fingers hands arms and shoulders may cause soreness swelling numbness weakness and extreme pain in t...

Page 6: ...mplete stop before removing obstructions clearing debris or servicing unit DO NOT start or operate unit unless all guards and protective covers are properly assembled to unit NEVER reach into any open...

Page 7: ...l cannot be read a new one can be ordered from your ECHO dealer See PARTS ORDERING instructions for specific information 1 2 4 6 7 9 10 3 8 11 12 13 P N X505002310 P N X505002080 Hot Decal near muffle...

Page 8: ...8 Spark arrestor muffler or spark arrestor muffler with catalyst The muffler or catalytic muffler controls exhaust noise and emission The spark arrestor screen prevents hot glowing particles of carbo...

Page 9: ...fter inserting main blower pipe into fan case so that line F meets locking ring C rotate locking ring clockwise 1 8 turn to lock mian blower pipe in place 5 Align groove H in fan head pipe with tabs G...

Page 10: ...ase locking ring C with a coin or screwdriver and rotate ring so that lock symbol A is at top of ring 2 Remove pipes from locking ring Operation WARNING Moving parts can amputate fingers or cause seve...

Page 11: ...T store a unit with fuel in its tank Leaks can occur Return unused fuel to an approved fuel storage container Storage Fuel storage laws vary by locality Contact your local gov ernment for the laws aff...

Page 12: ...o not allow the rope to snap back in Always hold the unit firmly 5 Recoil Starter Place the unit on a flat clear area Firmly grasp throttle grip with left hand and rapidly pull recoil starter handle r...

Page 13: ...ll recoil starter handle rope E until en gine fires IMPORTANT Recoil starter Use short pulls only 1 2 2 3 of rope for start ing Do not allow the rope to snap back in Always hold the unit firmly NOTE I...

Page 14: ...l handle with left hand and lower handle stand with right hand operating blower WARNING Engine exhaust IS HOT and contains Carbon Monoxide CO a poison gas Breathing CO can cause unconsciousness seriou...

Page 15: ...obstructions clearing debris or servicing unit Allow unit to cool before performing service Wear gloves to protect hands from sharp edges and hot surfaces maintenance intervals COMPONENT SYSTEM MAINT...

Page 16: ...stall the new filter air filter Level 1 Tools required 25 50 mm 1 2 in Cleaning brush Parts required REPOWERTM AIR FUEL FILTER KIT NOTE Clean daily 1 Close choke Cold Start Position This prevents dirt...

Page 17: ...mal Maintenance Any failure attributed to lack of maintenance is not warranted Cleaning Grill 1 Brush accumulated debris from crankcase intake grill above the fuel tank Cleaning Cylinder Fins 1 Remove...

Page 18: ...d attach spark plug lead 5 Tighten all screws securely Exhaust Port Cleaning Level 2 Tools required Wood or plastic scraper 4 mm Hex Wrench Parts Required As needed Heat Shield 1 Remove spark plug lea...

Page 19: ...usted when operating the engine below 1 100 feet ASL otherwise severe engine damage may result Level 2 Tools required Screwdriver tachometer Echo P N 99051130017 Parts required None NOTE Every unit is...

Page 20: ...e r e v o C l e u f h t i w d e l u o F e v i t c e f e d g u l P n i 6 2 0 0 m m 5 6 o t t s u j d A e c a l p e r r o n a e l C e c a l p e r r o n a e l C g u l p e c a l p e R s n u r e n i g n E...

Page 21: ...Place the stop switchs in the STOP position 3 Remove accumulation of grease oil dirt and debris from exterior of unit 4 Perform all periodic lubrication and services that are required 5 Tighten all sc...

Page 22: ...r with catalyst Fuel Mixed Gasoline and Two stroke Oil Fuel Oil Ratio 50 1 Power Blend X ISO L EGD ISO CD 13738 and J A S O M345 FC FD two stroke air cooled engine oil Gasoline Use 89 Octane unleaded...

Page 23: ...ntial or non income producing use will be covered by this limited warranty for five 5 years from date of purchase EXCEPTIONS For two stroke engine powered products the electronic ignition module flexi...

Page 24: ...e procedures stale fuel including failure to provide or perform required maintenance services as prescribed in the operator s manual Preventative maintenance as outlined in the operators manual is the...

Page 25: ...t SORE was designed built and equipped to conform with applicable EPA and C A R B emissions standards and that your equipment SORE is free from defects in material and workmanship that would cause it...

Page 26: ...26 notes...

Page 27: ...27 Power Blower Operator s Manual notes...

Page 28: ...presenting your unit for Warranty service repairs proof of purchase is required echo consumer product support If you require assistance or have questions concerning the applica tion operation or maint...

Reviews: