background image

  

678/03.05.23/V2 

 
 
 

 

 

P a g e

| 7

 

of 28

 

 

Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom 

T

 | +44 (0) 1527 857 814           

E

 

[email protected]

           

W

 | www.eccostove.com 

 

For all patents 

 See Addendum 

Chimney draft if less than 0.06 inches water guage will impair the stove performance and hence its 
capability to keep the door glass clean.   Your installer will check this for you. 
The whole stove body should be a minimum of 150°C to enable the air wash to operate satisfactorily on 
the inside of the glass face. (200°C is the optimum operating temperature). 
Do not load logs with the end grain pointing toward the glass as this will result in excessive glass 
blackening.  Always arrange the logs in a crossways fashion within the firebox.  We cannot guarantee 
that the stove glass will not blacken.  However, high temperature (150°C +) burning with the secondary 
air control in use will clear the glass.  (200°C is the optimum operating temperature). 

 
7. AIRATED BACK PLATES 
 

The back panels (pre-drilled vermiculite or ceramic coated panels at the rear of the stove) are 
consumables and will deteriorate in use.  The panels are not covered by the 

manufacturer’s

 warranty. 

 
Damage can be caused by excessive firing but more usually by logs being smashed against them when 
loading stove.  Loading must be carried out with care.   
 
 

8. ASH GRATE 

 

 
The grate within your Eco Stove is made from cast iron being a highly durable material providing ash is 
not allowed to sit in the grate bars from the ash tray beneath. 
 
Ash removal is recommended before the grate bars become flooded with ash.  The grate is easily 
removed by simply lifting it out through the opened glass door. 
 

9. ROPE SEALS 
 

Regular maintenance of the stove is in part related to rope seals.  Seals between the sections are factory 
fitted and may remain in place without maintenance unless the appliance is stripped and moved, at 
which time all compressive seals between sections must be replaced with like for like diameter rope or 
flat tape as fitted to the stove at the time of its construction. 
 
Door/ ash pit/cleaning plug and hob cleaning plug seals should be replaced when showing signs of wear 
or every two years whichever comes first.  Rope seals are not covered by the 

manufacturer’s

 warranty. 

 

10. FINISHES 
 

On initial firing and perhaps three to five firings after the initial period, your stove will produce what 
would appear to be toxic fumes and is often mistaken for smoke leaking out of the appliance.  The paint 

on the appliance will be “stoved” or cured by your early firings of the appliance.  Do not be concerned 

that this smoke (which does not smell as wood smoke wood, it has a factory smell associated with it). 
 

Summary of Contents for 678EC

Page 1: ...declare the whole or part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in...

Page 2: ...www eccostove com For all patents See Addendum ADDENDUM Patents United Kingdom 2 213 945 E 2 467 433 United States 10 627 112 9 523 505 Canada 2 691 409 Germany 60 2010 064 710 2 Belgium 2 213 945 E S...

Page 3: ...odifications to the appliance should be carried out without written consent of Landy Vent UK Ltd Only parts manufactured by Landy Vent UK Ltd shall be used within this appliance 1 INTRODUCTION 2 PURPO...

Page 4: ...URE H FLUE OUTLET DIMENSION AND POSITION I HEAT ENERGY STORED J CO CONCENTRATION 24 DUCTED WARM AIR 25 GENERAL A SAFE OPERATION DISTANCES COMBUSTABLE AND NON COMBUSTABLE B MODIFICATIONS C PARTS D CHIM...

Page 5: ...the UK The installer must be aware that all local regulations including those referring to National and European standards need to be complied with when installing the appliance Not every stove can b...

Page 6: ...a top flue connection subject to specific order If the installation demands a 45 elbow can be taken directly from the top of the stove and back into the chimney Brest and hence the chimney flue The f...

Page 7: ...ashed against them when loading stove Loading must be carried out with care 8 ASH GRATE The grate within your Eco Stove is made from cast iron being a highly durable material providing ash is not allo...

Page 8: ...RNING Never spray aerosols in the vicinity of the stove when the stove is under fire 11 AIR CONTROLS Your Ecco Stove has three systems of air inlets for combustion 11A TERTIARY AIR MODEL 678EC The aer...

Page 9: ...50 C or above It is important to note that the stoves performance is directly relative to the flue chimneys draft The stronger the draft the faster the stove will heat from cold and respond to the air...

Page 10: ...ny wet items such as fire cements or adhesives for rope seals are allowed to dry before lighting the stove When the stove is first lit check all seals for soundness and check the flue is functioning c...

Page 11: ...down no kindling needed 1 2kgs split logs maximum length 300mm maximum 60mm cross section load logs 2 crossways and 2 backwards in a splayed fashion with bark facing down with ashpit open maximum 1mm...

Page 12: ...r door frame which holds the curve double leaf front of the baffle up in place Lift the weight of the baffle off the pins remove the pins and the baffle will hinge down and rest on the stoves grate ba...

Page 13: ...draw would overfire the appliance To remove ash collected in the ash draw simply pull out the ash draw to its quarter extended position pull up safety catch lever on the side of the ash draw upon whic...

Page 14: ...fuelling is carried out on a bright or lively fire if the stove body is below 150 C Open the door to the fire box slowly when re fuelling to minimise smoke spillage into the room as the door will crea...

Page 15: ...r linings or coatings are suitable materials but ideally with a maximum flue area of 225 x 225 mm Pumice hot face linings with insulation or leka pelletts are suitable Under no circumstances should th...

Page 16: ...by improving flue performance immediately Clean any tar deposits off the door glass b Repairs or replacements must be carried out by a competent engineer Flueways are accessed by removing the cleaning...

Page 17: ...acer blocks one fixed front grate plug Two slide in vermiculite flueway dividers for left and right sides one cast iron grate Eleven further non structural parts are included being door section and fr...

Page 18: ...No seals are fitted to this part Ensure it is located on its domed carbide locating pips by shuffling to bed into place Ba Fit the cast iron grate into the recess within the Silicon Carbide grate sec...

Page 19: ...to the groove down left and right hand sides and across the grate section to enable the door frame to seal onto NOTE The tertiary air intake hole should be at the bottom and not the top of the back se...

Page 20: ...at expansion joint used such as ceramic glass tape and then sealed with fire cement I It will be necessary to beat the trims into shape for an improved fit to reduce gaps as each piece moulds differen...

Page 21: ...ue draught to be 04 inches water gauge f Flue gas mass flow 9 1 gs g Flue gas temperature Average 137 C at nominal output h Flue outlet 150mm top exit Dampers may be necessary if the flue draught is i...

Page 22: ...amage leave the air controls fully open Recycling To dispose of the stove after the product life has expired please observe the following information o Dispose of the items correctly i e separate the...

Page 23: ...supply and design The following parts are packed with the Ecco Stove 1 x Bottom section silicon carbide Ashcan 2 x alloy cleaning pugs 1 fixed alloy disc Model 850 only 1 x alloy t shaped joint seal l...

Page 24: ...y be run day and night by repeated firings but will not burn for more then 2 4 hours on one filling or refuelling dependent on how well the fire draws and the density of fuel being burned and after wh...

Page 25: ...ove com For all patents See Addendum Ecco Stove 678EC2 Description Value Nominal Heat Output 10 3 Net Efficiency 83 9 Particulate emissions 13 O2 mg m 21 OGC 13 O2 mg m 112 CO 13 O2 mg m 480 NOx 13 O2...

Page 26: ...05 23 V2 P a g e 26 of 28 Ecco Stove Foster House 2 Redditch Road Studley B80 7AX United Kingdom T 44 0 1527 857 814 E sales eccostove com W www eccostove com For all patents See Addendum ECCO STOVE W...

Page 27: ...pleted and returned to the Company within 21 days of installation see last page This warranty is void if the appliance is stripped and re assembled 3 Warranty Period Silicon Carbide parts are warrante...

Page 28: ...the use of wood logs on your Ecco Stove Coals or processed petro chemical fuels void the warranty as their use may produce blockage in flueways Wood logs must be seasoned dried to 20 25 humidity to pr...

Page 29: ...BY ADDRESS POSTCODE OR ZIPCODE TELEPHONE NUMBER INSTALLERS REGISTERED BODY AND NUMBER DATE THE ECCO STOVE WAS INSTALLED SELLING AGENT DEALER COMPANY NAME ADDRESS POSTCODE OR ZIPCODE TELEPHONE NUMBER E...

Page 30: ...lake on the stoves outer body This typically occurs after re firing when the stove has periods without use during the colder weather or when building works such as fresh plaster have taken place in an...

Reviews: