MAINTENANCE
Only perform maintenance work on the XRGI
®
system when it is not in
operation and is fully cooled down! Otherwise, there is a risk of burns from
hot components and/or scalding if substances should escape.
REQUIRED MATERIAL
EC POWER service kit for XRGI
®
15 (Item No.:
01KIT2503) consisting of:
1 pc. air filter
3 pcs. engine oil
1 pc. plug for measuring point
4 pcs. spark plugs
1 pc. oil filter
REQUIRED TOOLS
Oil suction pump
Torque wrench
Oil filter spanner
17 mm socket insert
Water pump pliers
20.8 mm spark plug wrench
Funnel
3 mm Allen screwdriver
feeler gauge
5 mm Allen screwdriver
FS2009USB programming device
17 mm open-ended spanner
Flue gas analyser
Before commencing maintenance work, shut down the XRGI
®
system at
the user level on the iQ-Control Panel and at the main switch. Close the
gas valve and unplug the Q-Heat Distributor.
6.
MAINTENANCE XRGI® 15
Fig. 6.01
29