Chengdu Ebyte Electronic Technology Co.,Ltd.
E104-BT12LSP User Manual
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
32
Metal objects near antennas, or placed in metal shells, attenuated signals.very serious;
Incorrect power register setting, excessive air rate (air rate)the higher the distance, the closer;
At room temperature, the lower the voltage, the lower the power.
7.2 Module is easy to damage
Check the power supply to ensure that permanent damage to the module occurs between recommended supply
voltages, if exceeded;
Please check the stability of the power supply. The voltage cannot fluctuate significantly and frequently.
Please ensure anti-static operation during installation and high frequency device electrostatic sensitivity;
Please ensure that the installation process is not too humid. Some components are humidity sensitive.
If there is no special requirement, it is not recommended to use it at too high and too low temperatures.
7.3 The error rate is too high
There is interference from the same frequency signal nearby, away from the source of interference, or from
modifying frequency and channel;
The clock waveforms on the UART are not standard. Check for interference on the UART line;
Poor power supply may also cause confusion. Be sure to ensure the reliability of the power supply;
8. Welding instruction
8.1 Reflow Welding Temperature
Profile Feature
Curvilinear characteristics
Sn-Pb Assembly
Pb-Free Assembly
Solder Paste
Tin ointment
Sn63/Pb37
Sn96.5/Ag3/Cu0.5
Preheat Temperature min
(
Tsmin
)
Minimum
preheating
temperature
100
℃
150
℃
Preheat temperature max (Tsmax)
Maximum
preheating
temperature
150
℃
200
℃
Preheat Time (Tsmin to Tsmax)(ts)
Preheat time
60-120 sec
60-120 sec
Average ramp-up rate(Tsmax to Tp)
Average ascent rate
3
℃
/second max
3
℃
/second max
Liquidous Temperature (TL)
Liquidus temperature
183
℃
217
℃
Time
(
tL
)
Maintained Above
(
TL
)
Time above liquidus
60-90 sec
30-90 sec
Peak temperature
(
Tp
)
Peak temperature
220-235
℃
230-250
℃
Aveage ramp-down rate
(
Tp to Tsmax
)
Average descent rate
6
℃
/second max
6
℃
/second max
Time 25
℃
to peak temperature
Time from 25
℃
to peak
temperature
6 minutes max
minutes max