01 will be added before the data
4.4.2 Disconnection and reconnection function
In client mode, the device attempts to actively connect to the server at a specified time after the
network is disconnected.
Disconnection reconnection time: The time interval between each attempt to reestablish the
network by the device, 0 is a fast reconnection, and 0 ~ 65535 can be configured.
4.4.3 Timeout restart function
Support timeout restart function (default: 1800 seconds), which is mainly used to ensure the
long-term stable operation of the equipment. If the data sent by the network is not received within the
set timeout restart time, the equipment will restart, thus avoiding the influence of abnormal
conditions on communication.
When the timeout restart function is turned on, the timeout restart time setting parameter ranges
from (60-65535) seconds.
4.4.4 Short connection function
In TCP client and HTTP client mode, short network connection is supported (this function is
turned off by default). TCP short connection is mainly used to save server resource overhead, and is
generally applied to multi-point (multi-client) to one-point (server) scenario.
After the short connection function is turned on, it only requests to connect with the server
when sending information. After the connection is successful, the device will automatically
disconnect if the serial port does not receive the pilot data or the network port does not send and
receive data within the set time.