NB183S&NB183_User Manual
Copyright ©2012–2022
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
7
2.2 Software Preparation
Serial debugging assistant (XCOM), network debugging assistant (TCP/IP debugging assistant), Ebyte network
configuration tool (configuring the host computer), official website address: www.ebyte.com, product details provide
download interface.
Network Assistant
XCOM
亿佰特网络配置工具
[Note] The host computer displayed in the manual may be different from the superior version provided on the official
website. The host computer provided on the official website shall prevail.
2.3 Test steps of device default parameters
Different channels use the same IP and different local ports. For example, the factory-configured channel 1 corresponds
to port 8001 and channel 8 corresponds to port 8008 in turn. For details, see the "Correspondence between Channels and
Serial Ports" chapter.
2.3.1 Connecting the hardware
1. Use a network cable to connect the serial port server network port and the computer network port;
2. Use a USB to RS485 serial cable to connect the USB port of the computer and the RS485 interface of the serial server;
3. Use the power adapter (DC 8-28V) to power on the device, and observe whether the indicator light is normal after
power-on, refer to "Indicator Indicator";
4. After confirming that there is no problem with the status, proceed to the next configuration;
2.3.2 Device parameter configuration
In order to enable users to quickly have a simple understanding of the serial port server, we use the default parameters of
the serial port server to conduct data transparent transmission test. The default parameters of the NB183 serial server
device are shown in the table below.
Project
default parameters