1.Overview

1.1 Introduction

Based on TI CC1352P chip, E79-400DM2005S is a dual-band ARM-based RF SoC Module

designed by Ebyte, with max transmitting power of 20dBm at SUB-1GHz and 5dBm at 2.4GHz.
The module integrates a high-performance wireless transceiver and a low temperature drift
industrial crystal oscillator.

Presenting all the IO interfaces of the micro-controller and integrating a powerful 48 MHz

Arm ® Cortex ® -M4F processor, high-performance power amplifier, powerful peripherals and up
to 26 GPIOs for multi-faceted development, The module can be developed into many application
fields. It is an excellent choice for wireless micro-controller for Smart home, IoT upgrading and industrial automation etc.

The module is a hardware platform and cannot be used directly. Users need to conduct secondary development (Ebyte can

customize standard LoRaWan and Alibaba linkWan nodes for you).

1.2 Main Features:

Built-in high-performance low-power Arm ® Cortex ® -M4F processor with clock speeds up to 48MHz;

Rich resources, 352KB FLASH, 80KB RAM;

2.1~3.8V power supply voltage, Above 3.3V can guarantee the best performance;

Maximum transmitting power 20dBm@ SUB-1GHz/5dBm@ 2.4GHz, multi-level adjustable from software;

Under ideal conditions, the communication distance can reach 1.5km@SUB-1GHz/[email protected];

Module contains 48M high speed crystal / 32.768k low speed crystal;

Industrial grade standard design, support long-term use from -40 to +85 °C;

Double antennas are optional (IPEX/stamp hole), users can choose according to your own needs;

2 pin cJTAG and JTAG debugging;

Wireless upgrade (OTA);

Dual-band sub-1GHz and 2.4GHz RF transceivers compatible with Bluetooth 5 and IEEE 802.15.4 PHY and MAC

standards;

Excellent receiver sensitivity: –122dBm (SimpleLink long-distance), –110dBm (50kbps), –103dBm (Low-Power

Bluetooth 5 encoding).

1.3 Applications:

Smart grid and automatic meter reading

– water meters, gas meters and electricity meters
– heat distribution table
– gateway

Wireless sensor network

– Remote sensor security system, positioning system

Industry

– Asset tracking and management

Summary of Contents for E79-400DM2005S

Page 1: ...1 E79 400DM2005S User Manual CC1352P Dual Band SoC Wireless Module ...

Page 2: ... 2 1 LIMIT PARAMETERS 4 2 2 WORKING PARAMETERS 4 3 SIZES AND PINS DEFINITION 6 4 PROGRAMMING AND TESTING 7 5 USER GUIDE 7 5 1 NOTICE FOR HARDWARE 7 5 2 PROGRAMMING 8 6 FAQ 9 6 1 COMMUNICATION RANGE IS TOO SHORT 9 6 2 MODULE IS EASY TO DAMAGE 9 6 3 BER BIT ERROR RATE IS HIGH 9 7 PRODUCTION GUIDANCE 10 7 1 REFLOW SOLDERING TEMPERATURE 10 7 2 REFLOW SOLDERING CURVE 10 8 PACKAGE FOR BATCH ORDER 11 9 R...

Page 3: ...and Alibaba linkWan nodes for you 1 2 Main Features Built in high performance low power Arm Cortex M4F processor with clock speeds up to 48MHz Rich resources 352KB FLASH 80KB RAM 2 1 3 8V power supply voltage Above 3 3V can guarantee the best performance Maximum transmitting power 20dBm SUB 1GHz 5dBm 2 4GHz multi level adjustable from software Under ideal conditions the communication distance can ...

Page 4: ...marks Min Max Input Voltage V 0 3 8 Permanent damage occurred when voltage is over 3 8V Blocking Power dBm 10 Low chance to be damaged for short distance transceiving Working Temp 40 85 Industrial Grade 2 2 Working Parameters SUB 1GHz Parameters Main Parameters Value Remarks Min Typical Max Working Voltage V 2 1 3 3 3 8 Voltage above 3 3V can guaranty Max TX power Tx Electrical Level V 3 3 5V TTL ...

Page 5: ...mption TX Current mA 10 5 Instantaneous power RX Current mA 7 5 Max TX Power dBm 4 4 5 5 RX Sensitivity dBm 103 BLE 5 Coding Parameters Value Remarks Reference Range 1500m SUB 1GHz Conditions Clear Sky Antenna Gain 5dBi Antenna Height 2 5m Air rate 1kbps 120m 2 4G Conditions Clear Sky Antenna Gain 5dBi Antenna Height 2 5m Air rate 1Mbps TCXO Frequency 48MHz 32 768k High rate at 48MHz Low Rate at 3...

Page 6: ...figurable universal IO Port see CC1352P1F3RGZ Manual 7 DIO_9 Input Output Configurable universal IO Port see CC1352P1F3RGZ Manual 8 DIO_10 Input Output Configurable universal IO Port see CC1352P1F3RGZ Manual 9 DIO_11 Input Output Configurable universal IO Port see CC1352P1F3RGZ Manual 10 DIO_12 Input Output Configurable universal IO Port see CC1352P1F3RGZ Manual 11 DIO_13 Input Output Configurable...

Page 7: ...4 Input Output Configurable universal IO Port see CC1352P1F3RGZ Manual 32 DIO_25 Input Output Configurable universal IO Port see CC1352P1F3RGZ Manual 33 DIO_26 Input Output Configurable universal IO Port see CC1352P1F3RGZ Manual 34 DIO_29 Input Output Configurable universal IO Port see CC1352P1F3RGZ Manual 35 DIO_30 Input Output Configurable universal IO Port see CC1352P1F3RGZ Manual 36 VCC Input ...

Page 8: ...m the module according to the strength of the interference If circumstances permit it is recommended to do proper isolation and shielding If there are wirings with large electromagnetic interference around the module such as high frequency digital high frequency analog power line the performance of the module will be greatly affected It is recommended to do proper isolation and shielding Try to ke...

Page 9: ...oom temperature is lower than 2 5V the lower the voltage the lower the transmitting power Due to antenna quality or poor matching between antenna and module 6 2 Module is easy to damage Please check the power supply source ensure it is 2 0V 3 6V voltage higher than 3 6V will damage the module Please check the stability of power source the voltage cannot fluctuate too much Please make sure antistat...

Page 10: ...eheat temperature max Tsmax Mx preheating temp 150 200 Preheat Time Tsmin to Tsmax ts Preheating time 60 120 sec 60 120 sec Average ramp up rate Tsmax to Tp Average ramp up rate 3 second max 3 second max Liquidous Temperature TL Liquid phase temp 183 217 Time tL Maintained Above TL Time below liquid phase line 60 90 sec 30 90 sec Peak temperature Tp Peak temp 220 235 230 250 Average ramp down rate...

Page 11: ...h Order 9 Revision History Version Date Description Issued by 1 0 2017 10 16 Initial version huaa 1 1 2019 7 26 Error correction Lyl About us Website www ebyte com Sales info cdebyte com Support support cdebyte com Tel 86 28 61399028 Ext 812 Fax 86 28 64146160 Address Innovation Center B333 D347 4 XI XIN road High tech district west Chengdu Sichuan China ...

Reviews: