
Chengdu Ebyte Electronic Technology Co., Ltd.
Copyright © 2012–2022 , Chengdu Ebyte Electronic Technology Co., Ltd.
41
CRM
( Set reporting
mode )
test comma
nd
AT+CRM=?
+CRM: " reportMode " , " reportInt
erval "
OK
query com
mand
AT+CRM?
+CTXP:<reportMode>,[reportInterval]
OK
set comman
d
AT+CTXP=<reportMode>,[r
eportInterval]
OK
Parameter D
escription
<reportMode>:
0- non-periodic reporting data;
1-periodic reporting data;
<reportInterval>: This parameter is only available when reporting
data periodically. Time interval for periodic reporting of data, uni
t: s.
For different DRs, the allowable minimum cycle is different, whic
h is defined by cycle level, as shown in the following table.
Rate\Period(s)\Level LV1 LV2
DR0 150 300
DR1 75 150
DR2 35 70
DR3 15 30
DR4 10 20
DR5 5 10
Return valu
e descriptio
n
Example
AT+CRM=1,10
OK
Precautions
Need to set before sending data