Chengdu Ebyte Electronic Technology Co., Ltd.
Copyright © 2012–2022 , Chengdu Ebyte Electronic Technology Co., Ltd.
27
OK
Precautions
Used in ABP, set or read DevAddr, return Y1Y2 … Y4, hexadeci
mal format, value 4 bytes.
command chara
cters
Command t
ype
command format
response
CAPPSKEY
( Set AppSKey
)
test comma
nd
AT+CAPPSKEY=?
+CAPPSKEY=<AppSKey:length is 3
2>
query com
mand
AT+CAPPSKEY=<value>
+CAPPSKEY:<value>
OK
set comman
d
AT+CDEVADDR =<value>
OK
Parameter
Description
<value>: Node AppSKey
Return valu
e descriptio
n
Example
AT+CAPPSKEY=AABBCCDD00112233AABBCCDD00112233
OK
Precautions
Use, set or read AppSKey in ABP, return Y1Y2 … Y16, hexadeci
mal format, value 16 bytes.
command chara
cters
Command t
ype
command format
response
CNWKSKEY
( set NwkSKey
)
test comma
nd
AT+CNWKSKEY=?
+CNWKSKEY =<NwkSKey:length is
32>
query com
mand
AT+CNWKSKEY?
+CNWKSKEY:<value>
OK
set comman
d
AT+CNWKSKEY=<value>
OK
Parameter
Description
<value>: Node NwkSKey
Return valu