Chengdu Ebyte Electronic Technology Co,;Ltd                                                                                                                          E70 -DTU (433NW30) user manual

 

Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co,;Ltd                                                                                                                                                       
8

 

4.

 

FAQ       

[Failed  to access the network]:  Please check if  the node PANID  setting is consistent with the coordinator when the nodes 
are unable to access the network 
[Garbled]:  One reason is  that the serial  baud rate does not match.  The o ther reason is that the power  supply capacity is 
insufficient. 
[High  delay]:  When the node sends data, if the current channel noise is too cloud, it will actively back off. After waiting 
for a period, the node will  idle and start sending. 
[Receive response time]:  When the node is configured as  dormant node, the maximu m  receiving delay may be equal to the 
configured period   

[Unable to communicate]:  The modem  must be connected to the network  to communicate  with the coordinator 
[Unable  to read parameter]:  Check  whether the baud rate of the serial  port is correct. You can query in the configuration  
mode. 
[Into the network  is too long]:  During  the network  access process, the node and the coordinator have a large number of 
information  exchanges. This process does not have any protection mechanism and the information is easily interfered. After 
a node fails to access the network for a single time,  it will  request again after a certain period of time. 

5.

 

Firmware Transmitting mode   

5.1.

 

Transparent transmission 

 

Format 

Values 

When the coordinator is set to transparent transmission, the coordinator will send broadcast message.  At this time, all  non-dormant 
nodes in the entire network will receive  data. 

 

 

5.2.

 

Short address transmission 

 

Format 

Values 

Coordinator short address transmission format: short a valid data 

00 00 or FF FF are broadcast address; 

Coordinator 

HEX 

Sending

00  01 AA BB CC 

Node A address 00 01 

HEX 

Receiving

AA  BB CC 

Node B address 00 02 

HEX 

Null 

Node C address 00 03 

Coordinator 

HEX 

FF FF AA BB CC 

Summary of Contents for E70-DTU

Page 1: ...Chengdu Ebyte Electronic Technology Co Ltd E70 DTU 433NW30 user manual E70 DTU 433NW30...

Page 2: ...0 SERIES 5 3 FUNCTION DESCRIPTION 5 3 1 PIN DESCRIPTION 5 3 2 PIN DEFINITION 6 3 3 DIMENSION 7 4 FAQ 8 5 FIRMWARE TRANSMITTING MODE 8 5 1 TRANSPARENT TRANSMISSION 8 5 2 SHORT ADDRESS TRANSMISSION 8 6...

Page 3: ...s wireless communication network applications Features Use AT command to configure parameters In the coordinator mode support broadcast transmission short address transmission and long address transmi...

Page 4: ...ools This datasheet choosesserialport assistant netconfig_V1 3 Please download the software driver from Ebyte official website 1 2 1 Test procedure The device is mode 4 as default using the external h...

Page 5: ...td 3 Use serial port assistant to change the mode of E70 DTU 433NW30 Enters into AT Command AT WMCFG Reading current operation mode AT WMCFG 0 Change to 0 mode coordinator mode AT RSTART Module restar...

Page 6: ...t Introduction 2 1 Electrical Parameter No Parameter Name Description 1 Size 82 62 25mm 2 Weight 116g 2g 3 Working frequency 433MHz 4 Transmitting power 30dBm 5 Power supply 8 28V DC Note Higher than...

Page 7: ...4 Operating current Transmitting 468mA 12V Receiving 24 2mA 12V 15 Operating temperature 40 85 Industrial grade 16 Operating humidity 10 90 17 Storage temperature 40 125 Industrial grade 2 2 E70 Serie...

Page 8: ...n Function 1 RS232 RS232 interface 2 485_A RS 485 interface A 3 485_B RS 485 interface B 4 GND Ground 5 VCC Power supply DC8 28V 6 PWR Power Indicator 7 LINK Network successfully established indicator...

Page 9: ...Chengdu Ebyte Electronic Technology Co Ltd E70 DTU 433NW30 user manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 7 3 3 Dimension...

Page 10: ...nable to read parameter Check whether the baud rate of the serial port is correct You can query in the configuration mode Into the network is too long During the network access process the node and th...

Page 11: ...m works in the coordinator mode In the coordinatormode the coordinator can set up the network coordinator is the central node of the network there must be a coordinator in the network The coordinator...

Page 12: ...nt the user needs to wait for more than 100ms to send the real data After the wake up byte is sent the userneeds to wait for 100ms to send the real data and the wake up data will be discarded After th...

Page 13: ...mand mode AT EXIT Parameter Description Null Response Exit AT Mode Example AT EXIT Note AT commands are invalid after exiting AT command mode 3 AT HELP Help command AT HELP Parameter Description Null...

Page 14: ...ffffffffffffff arebroadcast address Example AT TFICFG 0 8 AT TMCFG Setting Querying transport modeconfiguration reboot valid AT TMCFG Description Gets transport modeconfiguration Response TMCFG 0 AT T...

Page 15: ...rameter Response UBCFG 7 AT UBCFG Value Description Value 0 7 0 1200 1 2400 2 4800 3 9600 4 19200 5 38400 6 57600 7 115200 Example AT UBCFG 7 13 AT UPCFG Setting Querying the device parity parameter r...

Page 16: ...ency performance parameter Response TLCFG 0 AT TLCFG value Description Value 0 3 0 Low concurrency 1 Medium concurrency 2 High concurrency 3 Highest concurrency Example AT TLCFG 0 Note This parameter...

Page 17: ...ion but the delay of receiving coordinator will be even higher Low power node cannot receive broadcast data which transmitted by the coordinator The systemwill be reset if the node is powered on for m...

Page 18: ...1 20 2019 04 12 initial version Molly 1 00 2018 03 29 Initial version huaa About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com Thank you for using Ebyt...

Reviews: