Chengdu Ebyte Electronic Technology Co.,Ltd.
E106-xxxTxxS User Manual
Copyright ©2012–2023
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
19
Send to: CF CF C0 00 04 12 34 00 61
Return: CF CF C1 00 04 12 34 00 61
6
format error
Format error response
FF FF FF
7.2 Register description
No.
Functi
on
Name
Description
Remarks
00H
Read /
write
ADDH ADDH (default 0)
* Module address of high byte and
low byte;
* Note: When the module address
is equal to FFFF, it can be used
as a broadcast and listening
address, that is, the module will
not filter the address.
01H
Read /
write
ADDL ADDL (default 0)
02H
Read /
write
NETID NETID (default 0)
*
Network
address
for
distinguishing networks;
* When communicating with each
other.
03H
Read /
write
REG0
7
6
5
UART Serial Rate (bps)
* In general transmission mode,
the serial port wave rate can be
different, and the verification
mode
can
be
different.
Generally, it is suggested that
the baud rate of both sides is
the same;
* The serial port port rate of the
two modules that communicate
with each other in continuous
transmission mode must be the
same.
0
0
0
The serial port port rate is
2400
0
0
1
The serial port port rate is
4800
0
1
0
Serial port port rate of 9600
(default)
0
1
1
The serial port port rate is
19200
1
0
0
The serial port port rate is
38400
1
0
1
The serial port port rate is
57600
1
1
0
The serial port port rate is
115200
1
1
1
The serial port port rate is
230400
4
3
2
1
0
Airial rate (bps)
* Only applicable to the general
transmission mode, the user needs
to choose their own wireless
transmission rate;
* In continuous transmission
mode,
this
configuration
parameter
is
invalid
and
automatically calculated by the
module.
0
0
0
0
0
0.5K
0
0
0
0
1
1.5K
0
0
0
1
0
3.5K
0
0
0
1
1
5.5K
0
0
1
0
0
6.5K
0
0
1
0
1
11K
0
0
1
1
0
13K