FF FF FF

7.2 Register Description

No

Read

Write

Name

Description

Remarks

00H Read/wr

ite

ADDH ADDH

Default 0

* Module address high byte and

low byte.

* Note: When the module address

is equal to FFFF, it can be used

as a broadcast and listening

address, i.e.: the module will

not be address filtered at this

point.

01H Read/wr

ite

ADDL ADDL

Default 0

02H Read/wr

ite

NETID NETID

Default 0

* Network address, to distinguish

between networks.
* should be set to the same when

communicating with each other.

03H

Read/wr

ite

REG0

7

6

5

UART Serial port rate

bps

* Two modules communicating

with each other in general

transmission mode can have

different serial port baud rates

and different checksums, it is

generally recommended that

both communicating parties

have the same baud rate.

* The serial baud rate of two

modules communicating with

each other in continuous

transmission mode must be the

same.

0

0

0

The serial port baud rate is
2400

0

0

1

The serial port baud rate
is4800

0

1

0

The serial port baud rate
is9600

Default

0

1

1

The serial port baud rate
is19200

1

0

0

The serial port baud rate
is38400

1

0

1

The serial port baud rate
is57600

1

1

0

The serial port baud rate
is115200

1

1

1

The serial port baud rate
is230400

4

3

2

1

0

Air Speed

bps

* Only applicable to the general

transmission mode, the wireless

transmission rate to be selected by

the user himself.
* In continuous transmission

mode,

this

configuration

parameter is invalid and is

calculated automatically by the

module internally

0

0

0

0

0

0.5K

0

0

0

0

1

1.5K

0

0

0

1

0

3.5K

0

0

0

1

1

5.5K

0

0

1

0

0

6.5K

0

0

1

0

1

11K

0

0

1

1

0

13K

Summary of Contents for E610-433T S Series

Page 1: ...1 E610 433TxxS User Manual 433MHz 100mW 1W Wireless High Speed Link Module...

Page 2: ...RANSMISSION 12 5 3 BROADCAST ADDRESS 13 5 4 LISTENING ADDRESS 13 5 5 MODULE RESET 13 5 6 AUX EXPLAINED 13 5 6 1 Serial data output indication 13 5 6 2 Wireless transmission indication 13 5 6 3 Modules...

Page 3: ...Y TRANSMISSION DISTANCE 26 12 2 MODULE VULNERABLE TO DAMAGE 27 12 3 TOO HIGH BER 27 13 WELDING WORK INSTRUCTIONS 27 13 1 REFLOW TEMPERATURE 27 13 2 REFLOW PROFILE 28 14 OTHER RECOMMENDED MODELS 29 15...

Page 4: ...duction use modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited The information contained herein is provided...

Page 5: ...long distance communications and multiple networks running simultaneously in the same area supports user set communication keys which cannot be read greatly improving the confidentiality of user data...

Page 6: ...s building automation solutions wireless industrial grade remote controls healthcare products Advanced Meter Reading Architecture AMI automotive industry applications 2 Specifications 2 1 RF parameter...

Page 7: ...erial port baud rate 2 2 Working parameters 2 3 Working parameters Hardware parameters Unit Description Remark E610 433T30S E610 433T20S Packet length byte 55 No limit on package length in continuous...

Page 8: ...port baud rate bps 2400 230400 Packaging method SMD Stamp hole PA LNA Yes Only LAN Power amplifier low noise amplifier SAW Yes SAW filter Antenna interface IPEX 1 Equivalent impedance approx 50 Dimen...

Page 9: ...xternal TXD output pin 6 M1 Input very weak pull up In conjunction with M0 determines the 4 modes of operation of the module not suspended grounded if not in use 7 M0 Input very weak pull up In conjun...

Page 10: ...ensions and Pin Definitions Pin definition No Name Direction Remark 1 NC Empty feet 2 GND Module ground 3 NC Null pin 4 nNEST Output Module reset pin low reset 5 NC Empty pin 6 NC Empty Pin 7 NC Empty...

Page 11: ...le 20 M0 Input very weak pull up In conjunction with M1 determines the 4 modes of operation of the module not suspended grounded if not in use 21 M1 Input very weak pull up in conjunction with M0 dete...

Page 12: ...hengdu Ebyte Electronic Technology Co Ltd E610 433TxxS User Manual Copyright 2012 2023 Chengdu Ebyte Electronic Technology Co Ltd 12 5 Functions in detail 5 1 Targeted launch 5 2 Broadcast transmissio...

Page 13: ...shed the AUX outputs high and starts working normally according to the working mode formed by the combination of M1 and M0 Therefore the user needs to wait for the rising edge of AUX as the starting p...

Page 14: ...data over the wireless port it may be that the last packet of data is being transmitted Timing diagram of the AUX pins when the module receives data from the serial port 5 6 3 Modules are in the proce...

Page 15: ...of the output low conditions are met When all low conditions are not met the AUX outputs high 2 when the AUX output is low it means that the module is busy and no working mode detection will be perfor...

Page 16: ...the module has received wireless data and sent it out via the serial port it needs to finish sending it before it can enter the new operating mode So mode switching can only be effective when the AUX...

Page 17: ...g from the first frame of data until it has completed the data that the user needs to transmit This saves time in data packing and packetisation and greatly reduces the data latency time Data delay di...

Page 18: ...sion Recei ving When not transmitting data can be received normally 6 4 User configuration mode mode 2 Type When M0 1 and M1 1 the module operates in mode 3 Transmitting Unable to transmit wireless da...

Page 19: ...d channel Command Start address Length Parameter Send C1 05 01 Return C1 05 01 09 Example 2 Simultaneous reading of module address network address serial port airspeed Send C1 00 04 Return C1 00 04 12...

Page 20: ...ssion mode can have different serial port baud rates and different checksums it is generally recommended that both communicating parties have the same baud rate The serial baud rate of two modules com...

Page 21: ...register 0x01 RSSI 1 of the last received data Conversion formula dBm RSSI 2 154 Command format analysis Send C0 C1 C2 C3 start address read length Return C1 address read length read valid value Examp...

Page 22: ...ngth byte to indicate the signal strength at the time the data was received Conversion formula dBm RSSI 2 154 0 Close Default 1 Open 6 Transmission method For general transmission mode only For fixed...

Page 23: ...data and is unable to perform low power operations 4 The module resets the user parameters from mode 3 sleep mode to other modes or during a reset during which the AUX output goes low Trunking network...

Page 24: ...configuration and reading of parameters in the configuration of the upper computer the module address frequency channel network ID key are decimal display mode where the value range of each parameter...

Page 25: ...to connect the module VCC TX RX GND and control the M0 M1 level to enter the configuration mode Select the firmware upgrade tab in the official configuration tool click the Open File button to select...

Page 26: ...uency digital high frequency analogue power supply alignments which will also greatly affect the performance of the module it is advisable to keep them away from the module depending on the intensity...

Page 27: ...nterference from co channel signals near stay away from sources of interference or modify the frequency or channel to avoid interference Poor power supply to may also cause garbled codes be sure to en...

Page 28: ...2023 Chengdu Ebyte Electronic Technology Co Ltd 28 Slope of cooling Tp TL 6 S max 6 S min Room temperature to peak temperature time 6 minutes max 8 minutes max The peak temperature Tp tolerance of the...

Page 29: ...36 TTL E34 2G4H11 S 2 4G 11 0 13 SMD 12 19 TTL E34 2G4D11 S 2 4G 11 0 13 SMD 12 19 TTL E34 2G4H20 D nRF24L01 2 4G 20 2 5 DIP 21 36 TTL E34 2G4D20 D nRF24L01 2 4G 20 2 5 DIP 21 36 TTL E34 2G4H27 D nRF...

Page 30: ...Glue Stick Antennas 433M SMA J 2 0 52 Ultra Short Straight Omnidirectional Antenna TX433 JZG 6 Glue Stick Antennas 433M SMA J 2 5 62 Ultra short straight omni directional antenna TX433 JW 5 Glue Stick...

Page 31: ...Electronic Technology Co Ltd E610 433TxxS User Manual Copyright 2012 2023 Chengdu Ebyte Electronic Technology Co Ltd 31 16 Bulk packing methods 16 1 E610 433T30S Packaging Method 16 2 E610 433T30S Pac...

Page 32: ...ial version Ning 1 1 2023 02 9 New low power products Hao About us Technical support support cdebyte com Documents and RF Setting download link https www ru ebyte com Thank you for using Ebyte product...

Reviews: