6
Formatting error
Format Error Response
FF FF FF
7.2 Register Description
No
Read
Write
Name
Description
Remarks
00H Read/wr
ite
ADDH ADDH
(
Default 0
)
* Module address high byte and
low byte.
* Note: When the module address
is equal to FFFF, it can be used
as a broadcast and listening
address, i.e.: the module will
not be address filtered at this
point.
01H Read/wr
ite
ADDL ADDL
(
Default 0
)
02H Read/wr
ite
NETID NETID
(
Default 0
)
* Network address, to distinguish
between networks.
* should be set to the same when
communicating with each other.
03H
Read/wr
ite
REG0
7
6
5
UART Serial port rate
(
bps
)
* Two modules communicating
with each other in general
transmission mode can have
different serial port baud rates
and different checksums, it is
generally recommended that
both communicating parties
have the same baud rate.
* The serial baud rate of two
modules communicating with
each other in continuous
transmission mode must be the
same.
0
0
0
The serial port baud rate is
2400
0
0
1
The serial port baud rate
is4800
0
1
0
The serial port baud rate
is9600
(
Default
)
0
1
1
The serial port baud rate
is19200
1
0
0
The serial port baud rate
is38400
1
0
1
The serial port baud rate
is57600
1
1
0
The serial port baud rate
is115200
1
1
1
The serial port baud rate
is230400
4
3
2
1
0
Air Speed
(
bps
)
* Only applicable to the general
transmission mode, the wireless
transmission rate to be selected by
the user himself.
* In continuous transmission
mode,
this
configuration
parameter is invalid and is
calculated automatically by the
module internally
。
0
0
0
0
0
0.5K
0
0
0
0
1
1.5K
0
0
0
1
0
3.5K
0
0
0
1
1
5.5K
0
0
1
0
0
6.5K
0
0
1
0
1
11K
0
0
1
1
0
13K