C2+operating
parameter
Send C2 + 5 bytes working parameter in hexadecimal format, a total of 6 bytes and
must be sent continuously(do not save when power off)
4
C3+C3+C3
Send three C3s in hexadecimal format. The module returns version information and
must be sent continuously.
7.1 Default parameters
Model
Factory default parameter value
:
C0 00 00 19 2E 00
Module type
Frequency Address
Channel
Air rate
Baud rate
Transmitting power
E49-900T20S
868MHz
0x0000
0x2E
2.4kbps
9600
20
7.2 Reading operating parameter
Instruction format
Detailed description
C1+C1+C1
In the setting mode (M0 = 0, M1 = 1), issue a command to the module
serial port (HEX format): C1 C1 C1,
The module will return the current configuration parameters,
such as: C0 00 00 18 20 00
7.3 Reading version number reading
Instruction format
Detailed description
C3+C3+C3
In the setting mode (M0 = 0, M1 = 1), issue a command to the module serial port
(HEX format): C3 C3 C3,
The module will return the current configuration parameters, such as: C3 49 xx yy;
49 here represents the module model (E49 series), xx is the version number, and yy
refers to other features of the module (users can ignore).