Chengdu Ebyte Electronic Technology Co., Ltd
E49-900T20S User Manual
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
14
2
Select 5V (the module supports 2.6 ~ 5.5V).
3
Run the "Serial Debug Assistant" software and select the correct serial port number and observe the sending
window and the corresponding receiving window.
7. Command format
Command mode (Mode 2: M0 = 0, M 1 = 1), the list of supported commands is as follows (when set, only 9600, 8N1
format is supported):
No.
Instruction format
Detailed description
1
C0+operating
parameter
Send C0 + 5 byte working parameters in hexadecimal format, a total of 6 bytes and
must be sent continuously (save when power off)
2
C1+C1+C1
Send three C1s in hexadecimal format. The module returns the saved parameters and
must be sent continuously.