7.1 Default parameters

Type

Default parameter values

C0 00 00 18 DC 44

Model

Frequency

Address

Channel

Air data rate

Baud rate

Parity

Transmittin

g power

E30-490T20D

490MHz

0x0000

0x96

1kbps

9600

8N1

100mW

7.2 Reading operating parameters

Instruction format

Description

C1+C1+C1

In sleep mode

M0=1

M1=1

),

User gives the module instruction (HEX format): C1 C1 C1,

Module returns the present configuration parameters.

For example, C0 00 00 1A 17 44.

7.3 Reading version number

Instruction format

Description

C3+C3+C3

In sleep mode

M0=1

M1=1

,User gives the module instruction (HEX format): C3 C3 C3,Module

returns its present version number, for example C3 32 xx yy. the second bytes means frequency. 32

here means the frequency is 433MHZ, 38 means frequency is 470MHz, 45 means frequency is;

868MHz, 44 means the frequency is 915 MHz, 46 means the frequency is 170MHz; xx is the version

number and yy refers to the other module features.

7.4 Reset command

Instruction format

Description

C4+C4+C4

In sleep mode

M0=1

M1=1

,

User gives the module instruction (HEX format): C4 C4 C4, the module resets for one time. During

the reset process, the module will conduct self-check, AUX outputs low level. After reset completing,

the AUX outputs high level, then the module starts to work regularly which the working mode can be

switched or be given another instruction.

7.5 Parameter setting command

No.

Item

Description

Remark

0

HEAD

Fix 0xC0 or 0xC2, it means this frame data is control command

Must be 0xC0 or 0xC2

C0: Save the parameters when power-down
C2: Do not save the parameters when power-down

1

ADDH

High address byte of module

the default 00H

00H-FFH

Summary of Contents for E30 Series

Page 1: ...E30 490T20D User Manual SI4438 490MHz 100mW DIP Wireless Module...

Page 2: ...FIXED TRANSMISSION 7 5 2 BROADCASTING TRANSMISSION 7 5 6 1 Indication of UART output 8 5 6 2 Indication of wireless transmitting 8 5 6 3 Configuration procedure of module 9 5 6 4 Notes for AUX 9 6 OP...

Page 3: ...action They are applicable in the industrial and living environment like a plant or indoors The module features FEC Forward Error Correction algorithm which ensure its high coding efficiency good corr...

Page 4: ...arameter 2 1 Limit parameter Main parameter Performance Notes Min Max Power supply V 0 5 2 Voltage over 5 2V will cause permanent damage to module Blocking power dBm 10 Chances of burn is slim when mo...

Page 5: ...ing Main parameter Description Notes Distance for reference 2500m Test condition clear and open area antenna gain 5dBi antenna height 2 5m air data rate 1 0kbps TX length 58 Byte Maximum capacity of s...

Page 6: ...M1 Input weak pull up Work with M0 to decide 4 working modes of module not suspended if not used could be grounded 3 RXD Input TTL UART inputs connects to external MCU PC TXD output pin Can be configu...

Page 7: ...d as push pull output suspending is allowed 6 VCC Input Power supply 2 3 5 5V DC 7 GND Input Ground 8 Fixed orifice Fixed orifice 9 Fixed orifice Fixed orifice 10 Fixed orifice Fixed orifice 4 Connect...

Page 8: ...r manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 7 5 Function description 5 1 Fixed transmission 5 2 Broadcasting transmission 5 3 Broadcasting address For example Set the addre...

Page 9: ...o work as per the operating mode combined by M1 and M0 Therefore users need to wait the AUX rising edge as the start of module s normal work 5 6 AUX description AUX Pin can be used as indication for w...

Page 10: ...rity should be given to the one with low level output which means if it meets each of any low level output condition AUX outputs low level if none of the low level condition is met AUX outputs high le...

Page 11: ...start to work in new mode after the transmitting finished Therefore the mode switch is only valid when AUX outputs 1 otherwise it will delay For example in mode 0 or mode 1 if the user inputs massive...

Page 12: ...ther 512 bytes continuously The data package transmitted from the module working in mode 0 can only be received by the module working in mode 0 or 1 Receivi ng The wireless receiving function of the m...

Page 13: ...e used for parameter setting It uses serial port 9600 8N1 to set module working parameters through specific instruction format pls refer to parameters setting for details Notes When the mode changes f...

Page 14: ...32 xx yy the second bytes means frequency 32 here means the frequency is 433MHZ 38 means frequency is 470MHz 45 means frequency is 868MHz 44 means the frequency is 915 MHz 46 means the frequency is 17...

Page 15: ...1 0 57600 1 1 1 115200 2 1 0 Air data rate bps The lower the air data rate the longer the transmitting distance better anti interference performance and longer transmitting time The air data rate must...

Page 16: ...r that works in mode 1 can be received 0 0 0 250ms default 0 0 1 500ms 0 1 0 750ms 0 1 1 1000ms 1 0 0 1250ms 1 0 1 1500ms 1 1 0 1750ms 1 1 1 2000ms 2 FEC switch After turn off FEC the actual data tran...

Page 17: ...red or placed over the Top Layer it is wrong to randomly route over the Bottom Layer or other layers which will affect the module s spurs and receiving sensitivity to varying degrees It is assumed tha...

Page 18: ...re are taken when installing and using high frequency devices have electrostatic susceptibility Please ensure the humidity is within limited range some parts are sensitive to humidity Please avoid usi...

Page 19: ...5 1k 25k DIP 21 36 SMA K E30 433T20S SI4438 433M 20 2 1k 25k SMD 17 30 IPEX External Spring E30 433T20D SI4438 433M 20 2 1k 25k DIP 21 36 SMA K 12 Antenna recommendation The antenna is an important r...

Page 20: ...rsion huaa 1 20 2018 01 29 Type merging huaa 1 30 2018 10 17 New added type huaa 1 40 2020 7 10 Li About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com T...

Reviews: