Chengdu Ebyte Electronic Technology Co., Ltd.
E22-230T22S User manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd.
18
Send:
C2
05
01
09
Returen: C1
05
01
09
E.g 2: Configure module address (0x1234), network address (0x00), serial port (9600 8N1) and
air data rate (1.2K).
Send: C2 00 04 12 34 00 61
Return: C1 00 04 12 34 00 61
5
Wireless
configuration
Command: CF CF + normal command
Respond:CF CF + normal respond
E.g 1: Channel is 0x09
Command head command starting address length parameter
Send:
CF CF
C0
05
01
09
Returen: CF CF
C1
05
01
09
E.g 2: Configure module address (0x1234), network address (0x00), serial port (9600 8N1) and
air data rate (1.2K).
Send: CF CF C2 00 04 12 34 00 61
Return: CF CF C1 00 04 12 34 00 61
6
Wrong format
Wrong format respond: FF FF FF
7.2 Register description
Address
Read
or
write
Name
Description
Remark
00H
Read/
Write
ADDH
ADDH(default 0)
The module address is high byte and low
byte. Note: When the module address is
FFFF, it can be used as the broadcast and
monitor address, that is the module will not
perform address filtering.
01H
Read/
Write
ADDL
ADDL(default 0)
02H
Read/
Write
NETID
NETID(default 0)
Network address, used to distinguish the
network. When communicating with each
other, they should be set to the same.