Chengdu Ebyte Electronic Technology Co.,Ltd.
E180-ZG120A User Manual
Copyright ©2012–2019, Chengdu Ebyte Electronic Technology Co.,Ltd.
1
6.6.29 Configure endpoint information
Endpoint_info
:
data format of 5 bytes are endpoint clusterId_H clusterId_L profileId_H profileId_L
Default is endpoint 0x01, clusterId 0xfeb0, profileId 0x0504
endpoint
clusterId
profileId
clusterId_H
clusterId_L
profileId_H
profileId_L
01
FE
B0
05
04
6.6.30 Set Link key of trust center
TrustCentLinkKey
:
data length of 16 bytes, default key of ZigBee alliance is
0x5A 0x69 0x67 0x42 0x65 0x65 0x41 0x6C
0x6C 0x69 0x61 0x6E 0x63 0x65 0x30 0x39
Take effect once restart
Note: Only the connected device holding the same link key (LinkKey) as the trust center (coordinator) can it connect to
the network of the trust center (coordinator), and the trust center (coordinator) transmits the network key to the connected
device , The connected device completes the process of joining the network to obtain the network key for normal
communication.
6.6.31 firmware version number
Firmware_version:
EF 32 02
EF 32
means EFR32 chip
02 means firmware version number
7.Quick start
7.1 Quickly build ZigBee network
Quickly and easily establish a ZigBee network via PC software. The steps are as follows:
(
1
)
Connect Zigbee ad hoc module via USB to UART converter, Open host computer software “ E180-ZG120A-Setting ” ,
select Com port and set baud rate as 115200(default), then open port.