Chengdu Ebyte Electronic Technology Co., Ltd
E104-BT10 User Manual
Copyright ©2012–2019
,
C
hengdu Ebyte Electronic Technology Co., Ltd
4-20
18. To obtain software version number
Operation
code
Parameter
Request
0x16
/
Respond
0x16
software version number
For
example
Request
:
02 C0 16
Respond
:
04 40 16 10 00
Notes
:
1
、
Suitable for E104-BT10-G and E104-BT10-N
2
、
software version number is an unique value
19.To obtain main address of current device
Operation code
Parameter
Request
0x0B
/
Respond
0x0B
Return main address of current E104-BT10-N device
For
example
Request
:
02 C0 0B
Respond
:
05 40 0B 01 0004
Notes
:
1
、
Suitable for E104-BT10-G and E104-BT10-N
2
、
return unicast address of E104-BT10-N device in current network
4.3.2 SIG Message
E104-BT10 supports SIG generic model and Lighting HSL model control ( refer to Mesh Profile and Mesh
Model for details about SIG message).SIG message follows format below
:
Transmitting
Command
(
1 byte
)
Target address
(
2 byte
)
Sig mesh message
0xC1
Main address of target
device
Request
Receiving
Command
(
1 byte
)
Target address
(
2 byte
)
Original address
(
2
byte
)
Sig mesh
message
0x41
Main address of target
device
Main address of
original device
Respond
For example
:
1
、
Generic onoff control
:
Control device with main address 0004, outputting high
level without latency
Request
09
C1
00 04 82 02
01
00 00 00
Respond
08
41
00 04 00 01 82 04
01
Control device with main address 0004, outputting low