Chengdu Ebyte Electronic Technology Co., Ltd
E104-BT10-IPX User Manual
Copyright ©2012–2019
,
C
hengdu Ebyte Electronic Technology Co., Ltd
4-20
1
、
Suitable for E104-BT10G-IPX and E104-BT10N-IPX
2
、
Status value 00 means succeed
18. To obtain software version number
Operation
code
Parameter
Request
0x16
/
Respond
0x16
software version number
For
example
Request
:
02 C0 16
Respond
:
04 40 16 10 00
Notes
:
1
、
Suitable for E104-BT10G-IPX and E104-BT10N-IPX
2
、
software version number is an unique value
19.To obtain main address of current device
Operation code
Parameter
Request
0x0B
/
Respond
0x0B
Return main address of current E104-BT10N-IPX
device
For
example
Request
:
02 C0 0B
Respond
:
05 40 0B 01 0004
Notes
:
1
、
Suitable for E104-BT10G-IPX and E104-BT10N-IPX
2
、
return unicast address of E104-BT10N-IPX device in current network
20.
Set whether enter sleep and timeout for entering sleep
Operation
code
Parameter
Request
0x17
/
Respond
0x17
Set whether E104-BT10N-IPX enter sleep and timeout for
entering sleep
For
example
Request
:
03 c0 17 05
Respond
:
03 40 18 05
Notes
:
1
、
Suitable for E104-BT10N-IPX
2
、
Set parameter 05 to the sleep timeout after the serial port stops working.
,
unit:
S, range: 0X01-0XFF
,
parameter 00 means do not enter sleep.