Chengdu Ebyte Electronic Technology Co.,Ltd.
E103-W10 User Manual
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
15
Data receiving
+IPD,0,n:xxxxxxxxxx
//receiving n bytes, contents
:
xxxxxxxxxxx
9. Close TCP connection
AT+CIPCLOSE=0
Response:
0, Close
OK
6 Network description
6.1 Network roles
No.
Note
1
E103-W10 module supports AP mode (equivalent to router), STATION mode (equivalent to Wi-Fi
device), STATION-AP mode, and up to 10 Wi-Fi devices at the same time in AP mode.
2
E103-W10 supports three Socket roles: TCP Server, TCP Client, and UDP. Up to 5 Socket
connections are supported simultaneously in TCP Server mode. TCP-based connectivity mechanisms,
if you need to be connected for a long time, be aware that you should use the TCP heartbeat pack.