C
hengdu Ebyte Electronic Technology Co.,Ltd
E95-DTU(400SL22-485) User Manual
C
opyright ©2012–2020, Chengdu Ebyte Electronic Technology Co.,Ltd
17
1
1
1
4000ms
07H
Write
CRYPT
_H
High byte of key
(default 0)
Only write, read returns 0;
Used for encryption to avoid interception of wireless data in the air by
similar DTUs;
The DTU will use these two bytes as a calculation factor to transform and
encrypt the air wireless signal.
08H
Write
CRYPT
_L
Low byte of key
(default 0)
80H
~
86H
Read
PID
Product information 7
bytes
Product information 7 bytes
7. Relay Network Mode Use
No.
Relay mode description
1
After setting the relay mode through the configuration mode, switch to the normal mode and the relay starts
to work.
2
In relay mode, ADDH and ADDL are no longer used as radio addresses, but correspond to NETID
forwarding and pairing respectively. If one network is received, it will be forwarded to another network.
The network ID of the repeater itself is invalid.
3
In the relay mode, the relay station cannot send and receive data, and cannot perform low-power operation.
4
When the user enters other modes from mode 3 (sleep mode) or is in the reset process, the radio will reset
the user parameters, during which AUX outputs low level.
Description of relay networking rules:
1
、
Forwarding rules, the relay can forward data in both directions between two NETIDs.
2
、
In the relay mode, ADDH\ADDL is no longer used as a DTU address, but as a NETID forwarding pairing.
As shown:
①
Primary relay
"Node 1" NETID is 08.
"Node 2" NETID is 33.
The ADDH\ADDL of relay 1 are 08 and 33 respectively.
So, the signal sent by node 1 (08) can be forwarded to node 2 (33)
At the same time, node 1 and node 2 have the same address, so the data sent by node 1 can be received by node 2.
Summary of Contents for 400SL22-485
Page 1: ...E95 DTU 400SL22 485 ...