Paragraph 4 - Operating the Printer
20070529#20.5
71
Stroboscope connector
(ST15 connector on the JET1-4 Board)
Fig. 4.4.4.8.4.
4.4.4.9. Switching the Stroboscope Over
NOTE:
The
STROBOSCOPE
command is strictly a service command that works with the
SET INK STREAM
command.
In the main MENU select the
SERVICE
item and then the
STROBOSCOPE
item.
High-contrast dots can be observed with a microscope, if the
STROBOSCOPE
command precedes the
SET INK STREAM
command The command electronically
switches the source of the synchronisation of the stroboscope LED light in the
microscope. The LED can flicker at the drop-break or row-print frequency. The
STROBOSCOPE
command switches sequentially between the "dot-based
synchronisation" to "raw-based synchronisation". If the
SET INK STREAM
command
is preceded by the
STROBOSCOPE
command, the completion of the adjustment of
the gutter height should be followed by the
STROBOSCOPE
command in order to
ensure that the "dot-based synchronisation" is switched to.
LED blinks at the drop-break
frequency
LED blinks at the row-point
frequency
Gutter
Fig. 4.4.4.9.1.
Position of ink drops in relation to the gutter for two settings of the stroboscope light
synchronisation
4.4.4.10. Monitoring High Voltage during Printing
In the main MENU select the
SERVICE
item and then the
HV VALUE,PHOTO,SHAFT,AirP state
item.
!