CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
93 / 116
- Keypad communication lost
- Keypad tamper
- Keypad power failure
- Time lost
10.2.
THE BEHAVIOR OF THE SYSTEM IN COMPATIBILITY MODE FOR
GRADE 2
The system operates in accordance with the EN 50131 standard requirements for Grade 2,
i.e.:
zones status is available only after user code has been entered
information about alarms is available only after user code has been entered
information about alarms memory is available only after user code has been entered
information about failures is available only after user code has been entered
information about failures memory is available only after user code has been entered
arming requires authorization
prior to arming, the control panel checks circumstances that may prevent arming
the codes in the system must be at least 5 characters
after entering an invalid code three times, all keypads in the system will be blocked
for 90 seconds.