CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
27 / 116
To display more detailed information about other damages, press
button.
1 – Clock fault
2 – Fault of central unit settings
3 –
Keypads tamper
To display more detailed information about keypads tamper, press
button.
1 – Keypad tamper 1
2 – Keypad tamper 2
3 – Keypad tamper 3
To return to the
Other damages
, press
button.
To return to the main fault menu, press
.
5.10.
TESTING THE ZONES
The function allow user to test zones and detectors connected to zones input.
<User code>
<Duration of test>
Duration of test is the time in seconds after which the test will be finished and the system
will return to the main menu.
After activation this function, LEDs 1 – 7 display the zones used in the system. Only zones
belong to the user’s partitions are presented. Relevant LED goes off after violation of the
zone. Example of use: walk around the protected object and activate detectors. After
activate detectors, relevant LEDs will go off. LEDs that are still on, indicate inactive or
broken detectors.
To exit the testing function press
or
.
5.11.
TESTING THE OUTPUTS
The function allow user to test outputs and alarm siren connected to the outputs.
< User code >
After activation this function, LEDs 1 - 3 display the outputs used in the system. Only
outputs defined as “alarm” type and belong to the user’s partitions are presented. Pressing
the key (1-3) activates relevant output (like an alarm), but not reporting the event to the
monitoring station. Thus the siren or other signalling devices can be checked. Repeated
pressing the key, disables the output.
To exit the testing function press
or
.
5.12.
DURESS CODE
Duress code is used to inform the monitoring station about a distress event. Each user has
his own duress code. User’s duress code is his standard code with last digit increased by
one. If the last digit is 9 it should be changed to 0. Example: