CPX200N ALARM CONTROL UNIT – INSTALLER MANUAL
79 / 106
Open a file with a new firmware (click [Open] to indicate a location of an appropriate
file),
Select the file transmission method: local.
Click [Start] button. The software replacement procedure will be initiated.
The course of recording is displayed in special software’s window.
Close the configuration wizard after you finish the recording.
Wait a few couple of seconds for the equipment to re-start.
Since now the equipment will operate under the control of a new firmware.
NOTE: The firmware update procedure shall be carried out with special
care as improperly performed operation can prevent the correct
operation of the equipment.
8.11.
DEVICE MONITORING
The function “Device Monitoring” allows the on-going monitoring of the control unit’s
condition. In order to use that functionality, connect the alarm control unit to a PC computer
via GD-PROG cable in DEBUG mode and then, in “Port” box select an appropriate RS232
port. Monitor allows the control of the following parameters:
Condition of mains power supply
GSM network signal strength and bit error ratio (BER)