EBS-6200
Printer User's Manual
Chapter 4 - Operating the Printer
40
200
subfile is to be a text file or a special register. You can
find it in the p
rd processor by
pressing the
§
Type
:
Text
The
Spec.reg.
parameter indicates whether a given
Char. set
:
Latin
25x15
Typeface
:
Normal
Distance
:
2
Rotation
:
None
arameter menu of the wo
key.
Spec.reg. :
None
T
g.
ara
owing special registers:
None
,
Univ.count.
,
an.
he
Spec.re
p
meter defines the foll
Up counter
,
Down count.
,
Time
,
Date
,
Univ. date
,
Date+offs.
,
Date+offs.2
,
Spec. ch
NOTE
:
Up to
6
special registers can be used in one complex text file.
!
Each of them is des
g section.
Object Counters
The following counters are used to print a consecutive number on every object automatically:
•
an incremental counter
,
•
a decremental
T
t
etector. An increment (varying from 1 to 9, in a
or
d
f
s is set with the
Counter delta
parameter, which is ava
the
PRINTING PARAM
While editing a sub
mber that
c
that the entire user-requested range is covered. The number
e initial
cribed in the followin
counter
.
y
to d
he counters are
escending order)
imed b a pho
or both counter
scending
ilable in
ETERS
command within the
PRINTING
submenu.
file that is to be used as an object counter, insert into the subfile a nu
onsists of so many digits
is th
s
te
etting of the coun r at th same
e
time. The number can be preceded and followed by any characters.
een put into a subfile, then:
tal counter – after 999 has been reache
EXAMPLE:
If number 056 has b
•
for the incremen
d, the counter is cleared and the
counting goes up from zero (056, 057, 058, ... , 999, 000, 001,
002, etc.),
•
for the decremental counter – after 000 has been reached, the counter is set to 999 and the
counting goes down to zero (056, 055, 054, ... , 000, 999, 998,
NOTE:
•
The
object counter
register is also used to print bar codes. Then the bar codes are printed
instead of consecutive numbers and the code corresponds to the consecutive number that is
ted by the special register. See section
4.4.1.2 Opening and Editing a New Text File
•
ter
special register can also count in the hexadecimal format. On
of the
Counter type
parameter from
DEC
(the default
setting standing for counting in decimal form) to
HEX
.
997, etc.).
91020#1.0
coun
paragraph
The
incremental coun
selecting the
Spec.reg.
=
Up counter
parameter from the subfile parameter menu, press the
§
key and then change the setting
!
Date and Time
The
Time
register is used to print current time in the 24-hour system on objects automatically.
The
Date
register is used to print current date in the leap year system on objects automatically.
The structure of the date and time registers is similar. If you edit a subfile that is to be a time (date)
register, follow the rules given below:
•
the time (date) register is built of up to 8 meaningful characters (6 digits to be updated and
2 separators),
•
when the register is updated, data is input starting from a non-space character until 8 defining
characters are inserted or until another space or the end-of-subfile are encountered,