CONTENTS

1. SAFETY REGULATIONS AND NOTES

1

1. SAFETY REGULATIONS AND NOTES

Please read these operating instructions carefully before starting to work
with the device. Observe the following warnings to prevent malfunctions
or physical damage to both property and people.
These operating instructions are to be regarded as part of this device.
If the device is sold or transferred, the operating instructions must
accompany it.
These operating instructions may be duplicated and forwarded for
information about potential dangers and their prevention.

1.1 Levels of hazard warnings

1

1.1 Levels of hazard warnings

These operating instructions use the following hazard levels to indicate
potentially hazardous situations and important safety regulations:

DANGER

Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury. Compliance with
the measures is mandatory. chapter

WARNING

Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury. Exercise extreme
caution while working.

CAUTION

Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury or damage of property.

NOTE

A potentially harmful situation can occur and, if not avoided, can
lead to property damage.

1.2 Staff qualification

1

1.2 Staff qualification

Only specialised electrical personnel may install the device, perform the
test run and work on the electrical system.
Only trained and authorised specialist personnel are permitted to
transport, unpack, assemble, operate or maintain the device, or to use it
in any other manner.

1.3 Basic safety rules

1

1.3 Basic safety rules

Any safety hazards stemming from the device must be re-evaluated
once it is installed in the end device.
Observe the following when working on the unit:

Do not make any modifications, additions or conversions to the
device without the approval of ebm-papst.

1.4 Electrical voltage

1

1.4 Electrical voltage

Check the electrical equipment of the device at regular intervals.

Remove loose connections and defective cables immediately.

DANGER
Electrical load on the device

Risk of electric shock

Stand on a rubber mat if you are working on an electrically
charged device.

WARNING
Terminals and connections have voltage even with a
unit that is shut off

Electric shock

Wait five minutes after disconnecting the voltage at all poles
before opening the device.

2

1.5 Safety and protective functions

2

1.6 Mechanical movement

2

1.7 Emission

2

1.8 Hot surface

2

1.9 Transport

2

1.10 Storage

2

1.11 Disposal

3

2. PROPER USE

4

3. TECHNICAL DATA

4

3.1 Graphic rendition of products

5

3.2 Nominal data

5

3.3 Technical description

5

3.4 Mounting data

5

3.5 Transport and storage conditions

6

4. CONNECTION AND START-UP

6

4.1 Connecting the mechanical system

6

4.2 Connecting the electrical system

6

4.3 Connection of the cables

7

4.4 Connection diagram

8

4.5 Checking the connections

8

4.6 Switch on device

8

4.7 Switching off the device

8

5. MAINTENANCE, MALFUNCTIONS, POSSIBLE

CAUSES AND REMEDIES

9

5.1 Cleaning

9

5.2 Safety test

Item no.: 10284-5-9970 · Revision status: KM73098 · Print-out on 01/02/2011 · Created by Y. Uhlmann (VM-TDO) · Page 1 of 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone: +49(0)7938/81-0 · Fax: +49(0)7938/81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R2E225-AT51-05

Page 1: ...cal system Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basi...

Page 2: ...working on rotating parts Protect long hair by wearing a cap 1 7 Emission WARNING Depending on the installation and operating conditions a sound pressure level greater than 70 dB A may arise Danger o...

Page 3: ...e operating instructions Improper use Using the device in the following ways is particularly prohibited and may cause hazards Moving air that contains abrasive particles Moving highly corrosive air e...

Page 4: ...ped 2 Accessory part Inlet nozzle 96358 2 4013 not included in the standard scope of delivery 3 Screw depth max 5 mm 4 Direction of rotation clockwise seen on rotor Item no 10284 5 9970 Revision statu...

Page 5: ...all bearing Mass 2 1 kg Material of impeller PA plastic 6 fibreglass reinforced Motor protection Thermal overload protector TOP wired internally Product conforming to standard CE EN 60335 1 Surface of...

Page 6: ...tion into leads or wires Water enters at the cable end on the customers side and can damage the device Make sure that the cable end is connected in a dry environment Connect the device only to circuit...

Page 7: ...n diagram U1 blue Z brown U2 black PE green yellow Item no 10284 5 9970 Revision status KM73098 Print out on 01 02 2011 Created by Y Uhlmann VM TDO Page 7 of 9 ebm papst Mulfingen GmbH Co KG Bachm hle...

Page 8: ...he device CAUTION Electrical load on the capacitor after device is switched off Electric shock risk of injury Discharge the capacitors before working on the device CAUTION The motor restarts automatic...

Page 9: ...tested How to test Frequency Protective casing against accidental contact Visual inspection at least every 6 months Device for damage Visual inspection at least every 6 months Mounting of device Visu...