background image

Operating and Maintenance Instructions 

210-OMI13848_Iss5.docx 

ORIGINAL INSTRUCTIONS 

Page 1 of 7 

 

 

ebm-papst UK Ltd 

 

Chelmsford Business Park  Chelmsford  Essex  CM2 5EZ

  

Telephone: +44(0)1245468555  Fax: +44(0)1245466336  
e-mail 

[email protected]

  

19/07/2022 09:04:36 

                                                                                                                             

 

  

 

 

Table of Contents 

1.0

 

Safety Notice .............................................................................................................................................. 2

 

2.0

 

Operating & Commissioning instructions .................................................................................................... 2

 

3.0

 

Introduction ................................................................................................................................................. 2

 

4.0

 

Specification ............................................................................................................................................... 3

 

5.0

 

Installation .................................................................................................................................................. 3

 

6.0

 

Mechanical Outline & Connection Detail .................................................................................................... 3

 

7.0

 

Connections ............................................................................................................................................... 5

 

8.0

 

Functions .................................................................................................................................................... 6

 

9.0

 

Transport and Storage ............................................................................................................................... 6

 

10.0

 

Maintenance and Servicing ........................................................................................................................ 6

 

11.0

 

CE Front Page ............................................................................................................................................ 7

 

 

List of Figures 

Figure 1 - Dimensions of the unit ............................................................................................................................. 3

 

Figure 2 - Mains and control connections ................................................................................................................ 4

 

Figure 3 - Wiring diagram below 1 A total load ........................................................................................................ 4

 

Figure 4 - Wiring diagram above 1 A total load ....................................................................................................... 5

 

Figure 5 - Graphs of the relationship of pot. setting to control voltage o/p .............................................................. 6

 

 

 

 

List of Tables 

 

Table 1 - Specification ............................................................................................................................................. 3

 

Table 2 - Connections ............................................................................................................................................. 5

 

Part No 

CN1102

 

Description 

3-way Switched Live Speed Selector 

 

 

 

Issue 

Date 

Bug no 

Comments 

17 Aug 2018 

N/A 

Update following CE review 

14 Sent 2018 

N/A 

Add CE cert front sheet, correct document number 

03 Nov 2020 

N/A 

Photograph and example circuits updated 

19 Jul 2022 

N/A 

Updated connection diagrams 

Summary of Contents for CN1102

Page 1: ...Storage 6 10 0 Maintenance and Servicing 6 11 0 CE Front Page 7 List of Figures Figure 1 Dimensions of the unit 3 Figure 2 Mains and control connections 4 Figure 3 Wiring diagram below 1 A total load...

Page 2: ...ce intended to be installed in a cabinet or enclosure The 3 speed switched live EC fan controller is designed for use with ebm papst electronically commutated fans with a three wire control interface...

Page 3: ...area within the user s equipment or within an enclosure that prevents access to live parts and reduces the risk of contamination by ingress of dust and moisture There is one mounting hole on the rear...

Page 4: ...elmsford Business Park Chelmsford Essex CM2 5EZ Telephone 44 0 1245468555 Fax 44 0 1245466336 e mail sales uk ebmpapst com 19 07 2022 09 04 36 Figure 2 Mains and control connections Controller connect...

Page 5: ...nt consumption greater than 1 0A or for an array of fans Figure 4 Wiring diagram above 1 A total load 7 0 Connections Screw Terminal Block Designation Connection 3 way 0 Fan Control GND Blue Wire 0 10...

Page 6: ...r output becomes active when mains live is applied to the corresponding input terminal Note the potentiometer range of adjustment is between 0 and 10 K When more than one fan is connected to the contr...

Page 7: ...210 OMI13848_Iss5 docx ORIGINAL INSTRUCTIONS Page 7 of 7 ebm papst UK Ltd Chelmsford Business Park Chelmsford Essex CM2 5EZ Telephone 44 0 1245468555 Fax 44 0 1245466336 e mail sales uk ebmpapst com...

Reviews: