10 | Wiring Diagram

Webasto

18 / 19

9039398A_WSM_eThermo_Top_Eco_EN

10.1

Legend to wiring diagram

No.

Description

Remarks

A1

Heater

e Thermo Top Eco

A2

Control unit

Power pack

A3

Control unit

Fan controller

A6

Relay socket

with fuses

A7

Gateway LIN
PWM

Fan controller

B1

Thermostat

Control thermostat

B2

Thermostat

Overheating protection

F1

Fuse 25A

Blade fuse DIN 72581-3

F2

Fuse 5 A

Blade fuse DIN 72581-3

F3

Fuse 3A

Blade fuse DIN 72581-3

F4

Fuse 16A

F5

Fuse 25A

Blade fuse DIN 72581-3

F6

Fuse 1A

Blade fuse DIN 72581-3

FI

Earth leakage cir-
cuit breaker

K1

Relay

Vehicle blower

M1

Motor

Circulation pump

M2

Motor

Vehicle blower

R1

Tubular heating
element

R2

Ballast resistor

Current limitation

S1

Switch

Vehicle blower

S2

Switch

Vehicle blower

V1

Diode

X1

2-pin plug con-
nection

To Item A1

X2

2-pin plug con-
nection

To Item A1

X3

3-pin plug con-
nection

To Item M1

X6

3-pin plug con-
nection

Connector with hinged lid

X9

3-pin plug con-
nection

To Item A1

X11

4-pin plug con-
nection

To Item A6

X12

4-pin plug con-
nection

To Item A6

0000015563A7

10.2

Legend for comments

No.

Description

Positive signal for activation of vehicle fan

Fuse for vehicle blower (fuse present in vehicle)

Air-conditioning control unit

10.3

Pin assignments plug connection
X1, 2-pin

No.

Description

1

Circulating pump positive

2

Circulating pump negative

10.4

Pin assignments plug connection
X2, 2-pin

No.

Description

1

Battery plus (terminal 30)

2

Battery minus (terminal 31)

10.5

Pin assignments plug connection
X9, 3-pin

No.

Description

1

Neutral conductor N

2

Protective earth conductor PE

3

Outer conductor L

10.6

Cable colours

Abbreviation Colour

Abbreviation Colour

bl

blue

rt

red

br

brown

sw

black

ge

yellow

vi

violet

gr

grey

ws

white

or

orange

Summary of Contents for eThermo Top Eco 20 P

Page 1: ...Service Instructions eThermo Top Eco 20 P 30 P English...

Page 2: ...mensions 9 5 Malfunctions and troubleshooting 10 5 1 Cause of malfunctions 10 5 2 Table of causes of fault 11 6 Function checks 12 6 1 General information 12 6 2 Heater supply cable extension cable 12...

Page 3: ...from Webasto n improper use n Use of non genuine replacement units n Repairs or device replacement not carried out by a Webasto service workshop n Use of unsuitable accessories n Insufficient coolant...

Page 4: ...e power cable may feel a little more rigid this is a characteristic of the product NOTE Function of timer A commercially available timer switch can be used for this purpose 230 V For outdoor use the t...

Page 5: ...Overview Relay bracket eThermo Top Eco 20 P 30 P Coolant inlet Vehicle blower relay X1 connection for coolant pump and vehicle fan relay Coolant outlet Installation cable X2 voltage compensation for...

Page 6: ...ation of the heater the charge state of the vehicle battery is maintained to the extent possible The power con sumption of the coolant pump and of the vehicle battery cause only a slight reduction in...

Page 7: ...as soon as the power cable connected to the vehicle connection is inserted into the socket To switch off the power cable is first removed from the socket outlet with earthing contact and then from the...

Page 8: ...Permissible working pressure bar 2 5 Capacity of the heat exchanger I 0 25 Heater dimensions mm 181x133x91 Heater weight empty kg 1 4 IP class Heater IP 5K4K IPX9K Coolant pump 12 V Volume flow agains...

Page 9: ...Webasto Technical data 4 9039398A_WSM_eThermo_Top_Eco_EN 9 19 4 1 Dimensions 181 133 Fig 3 side 91 133 Fig 4 Front...

Page 10: ...ion is caused when there is one or more faults occur Possible faults are n Overvoltage Undervoltage n malfunctions of all components e g due to short circuit or break n overheating of heater n Incorre...

Page 11: ...and replace if necessary n Heater check wiring connections replace heater if ne cessary n Wiring harness check connections check fuse and re place if necessary Coolant pump and vehicle fan not starti...

Page 12: ...ck coolant circuit Bleed in accordance with vehicle manufacturer s spe cifications 4 Switch on the eThermo Top Eco 20 P 30 P The coolant pump should run This can be checked by listening The vehicle fa...

Page 13: ...eater must be replaced Once the heater and all coolant carrying components have been installed the entire coolant system should be filled bled and checked for leaks at the system pressure as specified...

Page 14: ...ll the eThermo Top Eco 20 P 30 P without damage The coolant system must not be pressurised u If necessary remove additional parts so that the heater can be removed and reinstalled safely u Open the ve...

Page 15: ...he heater u Pull off the 230 V heater supply cable u Pull off the 12 V connections u Remove the bracket screws u Pull off the coolant hoses u Collect coolant in a suitable container u Remove the eTher...

Page 16: ...ure that the remaining coolant cannot leak out Close off the coolant connection pieces with dummy plugs n Storage and packaging The heater can be stored in any position Cover the heater and protect th...

Page 17: ...Webasto Wiring Diagram 10 9039398A_WSM_eThermo_Top_Eco_EN 17 19 10 Wiring Diagram 9035848A05 Fig 12 Wiring DiagrameThermo Top Eco 20 P 30 P...

Page 18: ...pin plug con nection To Item A1 X2 2 pin plug con nection To Item A1 X3 3 pin plug con nection To Item M1 X6 3 pin plug con nection Connector with hinged lid X9 3 pin plug con nection To Item A1 X11...

Page 19: ...ne number of each country can be found in the Webasto ser vice centre leaflet or the website of the respective Webasto representative of your country www webasto com Webasto Thermo Comfort SE Postfach...