- 6 -
EBARA
Corporation
4
Product specification
For the performance of your pump, refer to the nameplate in terms of total head (HEAD), discharge rate
(CAP.), rated voltage (V), rated current (A), etc.
Warning
The user of a standard model shall refer to the columns of standard specification.
Other than the standard model, a modified specification is available as a special
specification on request of the user. Do not use the pump at outside the range of
the specification, such as handling liquid, installing site, and power source.
Operation at outside the specification may cause pump trouble, injury, electric
shock, electric leak, and fire.
Mount a ground fault breaker exclusive to the pump. Recommended one is a
wiring breaker equipped with an electric leak alarm. There is a possibility of
electric shock and fire.
Caution
The pump cannot be used for food processing, food transportation, and other
food-relating uses. There is a possibility of generation of various bacteria and of
inclusion of foreign matter.
Do not use the pump at facilities for organisms (fish farm, fish preserve, aquarium,
etc.) There is a possibility of extinction of organisms caused by leak current or by
leakage of enclosed liquid from mechanical seal.
Do not use the pump at an important facility (computer cooling apparatus, cooling
apparatus for refrigerator, etc.)
Since machining oil, rubber-releasing agent, and foreign matter, used in pump-
production line, enter the handling liquid, operation of the pump shall be done
after fully flushing the pump to confirm the absence of foreign matter, depending
on the facility.
Limit the handling liquid to water. Do not handle oil, seawater, organic solvent,
etc., other than water. These liquids cause trouble of pump to result in electric
leak and electric shock.
The pump is a submersible sewage pump. Do not operate the pump for a long
period of time or under vigorous startup-shutdown conditions. Such operations
may lead to liquid leak from mechanical seal to induce trouble of the pump within
a short period of operation.
Install a stand-by pump preparing for an accidentally stop of the operating pump.
There is a possibility of suspension of water supply to stop the facilities.
■Standard specification
Handling
liquid
Liquid property
Liquid temperature
Liquid containing foreign matter
(PH 5-9, concentration of residual free chlorine: 10mg/L or
less, Concentration of chlorine ion: 200mg/L or less)
0-40°C
:
Non-automatic type
Size of
foreign
matter
Max.
(mm)
Diameter
of
spherical
shape
- 76 mm (DML)
- Equivalent to the pump diameter (DMLV)
Length
of
fibrous shape
- 500 mm (DML)
- DMLV Ø80 : 400 mm
- DMLV Ø100 : 500 mm
Max. submersible depth of the pump
Refer to Fig.1
Pump
Structure
Impeller
Shaft seal
Bearing
Single channel non-clog (DML)
– Vortex (DMLV)
Single coil-double mechanical seal
Sealed ball-bearing (inside the motor)
Material
Casing
Impeller
Shaft seal
Sealed liquid at
shaft seal
FC200
DML : Cast iron: FC200 (except for 50Hz 22kW)
Cast iron: FCD400 (for 50Hz 22kW)
DMLV : Cast iron: FC200 ( 2,2 ÷ 11 kW)
Cast iron: FCD400 (15 , 22 kW)
SiC/SiC
:
sliding material at liquid side
Ceramics-carbon: sliding material at motor side
NBR
:
rubber material
Turbine oil ISO VG 32