2.2
Type of electrical wires
Depending on the installation, the type and number of devices installed, the number of cables needed can vary. The table
below shows the cables needed for a typical installation. The cables used in the installation must be IEC 60335 compliant.
Power supply line
Cable 3x1,5 mm
2
Motor cable (if not equipped)
4x1,5 mm
2
Min Cable, for long distances use a 4x2,5 mm
2
Flashing signal
Cable 2x1 mm
2
Antenna
Shielded cable type RG58
Key selector
Cable 3x0,5 o 0,75 mm
2
Photocell transmitter
Cable 2x0,5 o 0,75 mm
2
Photocell receiver
Cable 3x0,5 o 0,75 mm
2
2.3 Type of installation
These two simple diagrams show only one of the possible applications for this control unit. The risks inherent to the
“MACHINE” and the user’s requirements must be analyzed in depth in order to establish how many elements need to be
installed. All NOLOGO photocells have a system of synchronism that makes it possible to eliminate interference between
two pairs of photocells (for other details, see the instructions for the photocells).
In the diagram , photocells
“FOTO A”
in opening they have no effect, while it provoque a complete inversion during
closing.
“FOTO A2”
is the serial connection of
“FOTO A”
or
“ALT, FOTO B
” is the photocell working by closing and
opening.
2.4 Notes on connections
To guarantee operator safety and to prevent damaging the components, never make connections or insert wireless
receiver boards while the control unit is powered.
• Power the control unit through a 3 x 1.5 mm cable. If the distance between the control unit and the ground system
connection is more than 30 m, a ground plate must be installed in proximity to the control unit.
• If the motors do not have a cable, use the 4 x 1.5 mm
2
cable (open + close + ground), for long distances use
a 4x2,5 mm
2 .
• In connecting the part with an extremely low safety voltage, use cables with a minimum section of 0,5 o 0,75mm
2
.
• Use shielded cables if the length exceeds 30m and connecting the ground braid only from the side of the control unit.
• Do not connect the cables in underground cases even if they are water-tight.
• If they are not used, the inputs to the Normally Closed (NC) contacts must be jumpered to the common”.
• If the same input has more than one contact (NC), they are placed in series.
• If they are not used, the inputs to the Normally Open (NO) contacts are left loose.
• If the same input has more than one contact (NO), they are to be placed in series.
• The contacts must be mechanical and free of any potential.
Remember that systems for automatic gates and doors must be installed by highly qualifi ed technicians only and in full
compliance with current law.
4
FOTO B
FOTO A
FOTO A
FOTO A2
Application on sliding automation
Installations for swing gates
Summary of Contents for START S10
Page 21: ...NOTE 21 ...
Page 22: ...NOTE 22 ...
Page 45: ...NOTE 21 ...
Page 46: ...NOTE 22 ...
Page 67: ...NOTE 19 ...
Page 89: ...NOTE 21 ...
Page 90: ...NOTE 22 ...
Page 113: ...NOTE 21 ...
Page 114: ...NOTE 22 ...