Instructions/DSA Series Fly-Bar Kit
and Enclosure Connecting Kit
DESCRIPTION:
The DSA Fly-Bar Kit and Enclosure Connecting Kit are used for suspending DSA Loudspeakers.
WARNING:
Suspending anything, especially overhead of people, should be done with extreme caution. Always engage the services
of a certified professional who is qualified to determine the requirements for, and to implement overhead rigging. Only persons with
the knowledge of proper hardware and safe rigging techniques should attempt to suspend DSA Loudspeaker Systems overhead.
Failure to follow these precautions may result in equipment damage, injury, or death.
WARNING:
When suspending DSA Enclosures, the Threaded Standoffs, Support Strap Studs, and Connecting Strap Studs carry
the weight of the Loudspeaker as a shear load, transferring it to the Straps themselves. For proper transfer of the load, all Standoffs
MUST slide into the Half-Moon Cutouts and seat against the Support Straps. Do not, under any circumstances, suspend a
Loudspeaker if any Standoff is not fully seated against its Support Strap surface. Failure to follow this warning may result in equip-
ment damage, injury, or death.
CAUTION:
For each of these procedures, make sure the correct end of the Loudspeaker, Signal End or Power End, is “up”
for the intended application.
WLL
(Working Load Limit)
The Fly-Bar Kit will support the weight of any DSA Cluster permitted in the DSAPilot control software. The Enclosure
Connecting Kit is required for and will support the weight of additional Enclosures in over-under Clusters permitted in
the DSAPilot software. Permitted Clusters with side-by-side Enclosures require two Fly-Bar Kits, one for each Enclosure.
DSA Fly-Bar Kit Parts List, EAW P/N 0007445:
Item
EAW P/N Qty Description
A
0007197
1
Fly-Bar
B
0007526
2
3/8” Shackle
C
0007449
4
Support Strap
D
0006036
4
1/4-20 x 1” Bolt
E
0006035
8
1/4 in Flat Washer
F
103012
4
1/4-20 Lock Nut
G
RD0090
1
Instructions/DSA Series
Fly-Bar Kit and Enclosure
Connecting Kit (not shown)
H
0007221
8
1/4-20 Threaded Standoff
I
0007522
1
Loctite Threadlocker 242
DSA Enclosure Connecting Kit Parts List, EAW P/N 0007446:
Item
EAW P/N Qty Description
G
RD0090
1
Instructions/DSA Series
Fly-Bar Kit and Enclosure
Connecting Kit (not shown)
H
0007221
16
1/4-20 Threaded Standoff
I
0007522
1
Loctite Threadlocker 242
J
0007198
4
Connecting Strap
8. Repeat Steps 1 to 7 for a third Enclosure.
9. Apply one drop of Loctite 242 to each
tightened Standoff as shown in the
drawing. Once applied, allow the
Loctite to cure undisturbed for a
minimum of 6 hours or according to
its directions.
If you have any questions about installing or using the DSA Suspension Kit, please contact the EAW Application
Support Group for assistance:
EAW ASG
Tel
800-992-5013 (USA only)
One Main Street
Tel
508-234-6158
Whitinsville, MA 01588 USA
Fax
508-234-3776
E-mail asg @eaw.com
T h e L a w s o f P h y s i c s | T h e A r t o f L i s t e n i n g
EAW is the worldwide technological and market leader in the design and manufacture of high-performance, professional loudspeaker systems.
P/N RD0090 (A) 1JULY03
ENCLOSURE
SUPPORT STRAP
STANDOFF
SEAT STANDOFF
AGAINST STRAP
1/2" WIDE FLAT-TIP
SCREWDRIVER
1 DROP
LOCTITE
242
5. Screw a Threaded Standoff onto each
lower Stud of the Connecting Straps.
6. Ensure all Threaded Standoffs are
fully inserted into the Enclosure
Channel Cutouts and are seated
against the Support Straps.
7. Using a 1/2” wide,
flat-tip Screwdriver,
firmly tighten all
Standoffs.