background image

TECHNICAL SPECIFICATIONS CB523M

CINEMA SYSTEMS

DESCRIPTIVE DATA continued

DESCRIPTIVE DATA

Part Number

999825

LF Subsystem & Loading

2x15-in vented

MF Subsystem & Loading

1x10-in horn-loaded

HF Subsystem & Loading

1x1.4-in exit compression driver
on CD horn

Configuration

3-way, full range

Powering Mode

Tri-amplified

System Crossover

EAW CX300-CB523M

Cabinet Type (shape)

Rectangular

Enclosure Materials

LF-3/4-in Medium Density Fiberboard 
15 mm birch plywood baffle-MF/HF-MDF

FinishTextured black

Connectors

2x2-terminal barrier strips 
(LF and MF) plus 2x bind posts (HF)

Dimensions 

inches

millimeters

Height

69.41

1763

Width24.80

630

Depth17.75

451

Weights

pounds

kilograms

Net Weight (approx)

235

10.69

Shipping Weight (approx)

253

115.1

• Approved for use in THX®-certified theaters

• For medium-sized theaters

• Tri-amplified 3-way screen channel loudspeaker

The CB523M tri-amplified three-way full-range screen channel loud-
speaker system has been approved for use in THX® certified theaters.

Three-way  design  dramatically  advances  cinema  audio  quality  by
improving  the  naturalness  and  intelligibility  of  dialog,  eliminating
distortion  from  excessive  driver  excursion  and  extending  pattern
control into the lower octaves. 

The  two  component  system  includes  a  BV253C  dual  15-in  low 
frequency enclosure and an HK523M mid/high section.

The low frequency enclosure uses optimally tuned enclosure venting
to increase LF response while limiting driver excursion. This method
produces less distortion and minimizes driver strain while extending
LF response to the lowest octaves. The enclosure’s shallow dimension
allows convenient placement behind the screen.

The HK523M MF/HF section features a horn-loaded 10-in cone and a
high  power  1.4-in  exit  compression  driver  loaded  with  a  90°x45°
coverage pattern constant directivity horn.

The adjustable steel bracket attaching the MF/HF section to the LF
enclosure  can  be  positioned  at  one  of  three  mounting  points  for
optimum front/rear placement. The bracket allows the MF/HF section
to be aimed independently of the LF section in both the horizontal
and vertical planes and can be locked once it is positioned.

Input  connectors  for  the  LF  and  MF  sections  are  two-terminal 
barrier  strips  that  accommodate  bare  wire,  tinned  leads  or  spade
lugs. Bind posts for the high frequency section are located directly
on compression driver. The input panels are located on the sides and
top of the enclosures for convenient access in cramped installation
areas.

APPLICATION

PRODUCT INFORMATION

Reviews: