background image

DIL...-XHI(C)(V)...(-PI)

XTCEXF...(PI)

DIL...-XHI(C)(V)...(-PI)

XTCEXF...(PI)

0

DILM12-XMV

XTCEXMLB

+

+

+

+

DILA-XHI…-S(-PI)

XTCEXSAB(PI)...

DILM12-XSPR…

DILM12-XSPV(L)...

2 x

M4 x 16

DILM(C)7…M(C)15(-PI)

DILMP20(-PI)

XTCE(PI)

XTCEC

XTCEPI015B

XTCFPI02B

DILM12-XMV

XTCEXMLB

DILM12-XMV

XTCEXMLB

DILMC...-EA(-PI) + ZB...

DILM12-XHI…-PI

DILM(C)32-XHI…(-PI)

DILA-XHI…(-PI)

XTCEXFAC…(PI)

XTCEXFCLC…(PI)

XTCEXFCC…(PI)

DILM12-XHI…-PI

DILM(C)32-XHI…(-PI)

DILA-XHI…(-PI)

XTCEXFAC…(PI)

XTCEXFCLC…(PI)

XTCEXFCC…(PI)

XTCEXRSB…

XTCEXVSB…

XTCEXVSLB…

XTCEC(PI)... + XTOB...

DILA(C)(-PI)

DILM(C)7…M(C)15(-PI)

DILMP20(-PI)

DILM32-XHI(C)…(-PI)

DILA-XHI(C)…(-PI)

DILA-XHI…-S(-PI)

XTCE(PI)…B

XTCEC…

XTCF(PI)…B

XTRE(PI)
XTCEXF…(PI)

XTCEXFA…(PI)

XTCEXSAB(PI)…

DILA(C)-22 (…VDC)

+ DILA-XHI(C)(V)04

(13, 22, 31, 40)

+ DILA-XHIR11

XTRE(C)10B22…D

+ XTCEXFAC(C)04

(13, 22, 31, 40)

+ XTCEXFARC11

Mounting

place in position

latch in
slide

remove

1
2
3
4

1

2

3

4

2

1

3

DIL…-XHI(C)(PI)

XTCEX(PI)…(C)

DILA-XHI…-S(-PI)

XTCEXSAB(PI)...

DILA…-PI, DILM7-15-PI, DILMP20-PI, DIL…XHI-PI

XTREPI, XTCEPI….B, XTCFPI…B, XT(C)(R)EX…(PI)

0.5 - 2.5 mm

2

AWG20 - 12

AWG20 - 14

2

1 2 3

2

a = 10 mm

(0.39")

a

a

0.5 x 3

a = 10 mm

(0.39")

a

a

1 x (0.75 - 2.5 mm

2

)

2 x (0.75 - 2.5 mm

2

)

1 x (0.75 - 1.5 mm

2

)

2 x (0.75 - 1.5 mm

2

)

1 x (0.75 - 1.5 mm

2

)

2 x (0.75 - 1.5 mm

2

)

1 x (0.75 - 2.5 mm

2

)

2 x (0.75 - 2.5 mm

2

)

(0.75 - 2.5 mm

2

)

1 x

2 x (0.75 - 2.5 mm

2

)

18-14

AWG

DILMC…, XTCEC…,

DILAC…, XTREC…

DIL…-XHIC…

XTCEX…C…

0.6 x 3.5

DILM…, XTCE…,

DILA…, XTRE…

DIL…-XHI…,

XTCEX…

1 x (0.75 - 6 mm

2

)

18-14

AWG

2 x (0.75 - 2.5 mm

2

)

1 x (0.75 - 2.5 mm

2

)

2 x (0.75 - 2.5 mm

2

)

1 x (0.75 - 6 mm

2

)

2 x (0.75 - 2.5 mm

2

)

1 x (0.75 - 2.5 mm

2

)

2 x (0.75 - 2.5 mm

2

)

PZ2

1.2 Nm

(10.6 lb-in)

4.5 mm

(0.18")

0.5 - 2.5 mm

2

→ DIN46228-1

0.5 - 1.5 mm

2

→ DIN46228-4

35

mm

(1.38

")

2007

KW41

2

2

1

1

3

DILA-XHI(C)01(10)-S(-PI)

XTCEXSAB(PI)...

4

DILA-XHI(C)01(10)-S

XTCEXSAB…

≧ 4107

DILM7-15...-PI,DILMP20...-PI

XTCEPI…B,XTCF020B

DILM8-38…-11…-PI

XTCEPI…C,XTCFPI…C

DILA-XHI…-PI

XTCEXFACPI…

DILM12-XHI…-PI

XTCEXFABPI…

DILM32-XHI…-PI

XTCEXFDCPI…

0.5 - 2.5 mm

2

3.6

mm

(⌀

≦ 0.14”)

DANGER

The opening of the branch-circuit

protective device may be an indication that a

fault has been interrupted. To reduce the risk of

fire or electrical shock, current-carrying parts

and other components of the controller

should be examined and replaced if

damaged. If burnout of the element of

an overload relay occurs,

the complete overload

relay must be

replaced.

©

2003 Eaton Industries GmbH

Eaton.com/documentation

Eaton.com/aftersales

Eaton.com/recycling

Instruction Leaflet

04/22 IL03407013Z

EU:

Eaton

Industries

GmbH,

Hein-M

oeller-Straße

7-11,

53115

Bonn,

Germany

UK:

Eaton

Electric

Ltd.,

P.O.

Box

554,

Abbey

Park,

Southampton

Road,

Titchfield,

PO14

4QA,

United

Kingdom

Reviews: