4 Installation
4.4 Installing
20
XP-503
12/2014 MN048014-EN www.eaton.com
The following requirements and instructions must be observed without fail in order to
ensure that the XP-503 will run properly and will not be damaged.
4.4.1
Temperature
Prior to commissioning:
-
Slowly let the device settle into the existing ambient temperature.
-
If there is condensation in or on the device, do not switch on the device until it is completely dry.
Avoid overheating during operation:
Do not expose the device to direct sunlight or other sources of heat.
The ambient air temperature during operation must not exceed the maximum limit value specified
in the "Technical data" chapter.
4.4.2
Aeration and de-aeration
Do not block the ventilation openings when mounting the device:
They are designed to allow air to circulate in order to cool the device.
The device uses natural convection-based passive cooling, i.e., it does not use CPU or system
fans.
The CPU and the power supply unit's power semiconductors are directly thermally connected to
the back of the display housing by means of a heat spreader or heat sink.
Make sure that there will be enough volume for air changes inside the control panel, etc. There
must be a clearance of at least 50 mm around the XP-503. The clearance behind it can be
reduced to 20 mm if necessary.
Make sure that there is enough air recirculation.
Example: XP-503-15
The following also applies to other device versions as applicable.
Abb. 1
Aeration and de-aeration
Summary of Contents for XP-503
Page 1: ...Manual 12 2014 MN048014 EN XP 503 Panel PC...
Page 6: ...1 General 1 3 Additional documentation 6 XP 503 12 2014 MN048014 EN www eaton com...
Page 10: ...2 Description of device 2 4 Designation 10 XP 503 12 2014 MN048014 EN www eaton com...
Page 18: ...3 Safety instructions 3 4 Device specific hazards 18 XP 503 12 2014 MN048014 EN www eaton com...
Page 30: ...4 Installation 4 8 External connections 30 XP 503 12 2014 MN048014 EN www eaton com...