26 Analog input/output module ±10 V XN-322-8AIO-U2
26.4 Diagnostics
XN300 slice modules
06/16 MN050002 EN
www.eaton.com
197
26.3.3 Measurements using sensors
In order to measure a sensor's output voltage via an analog input, a differen-
tial voltage measurement is carried out without connecting either input cable
to ground (GND). The signal being measured must fall within the input's per-
missible common mode range.
Figure 108:
Wiring for analog inputs in order to measure a sensor
26.4 Diagnostics
Cable break diagnostics will only be run for the analog inputs. The R voltage
reference outputs will be individually monitored for overcurrent, short-cir-
cuits, and an excessively high total current. Object 0x30B5 delivers the diag-
nostics – please refer to manual „CANopen Gateway XN312-GW-CAN“,
MN050003.
X1
1+ 1- 2+ 2-
4-
X2
3+ 3- 4+
X3
R
R
R
R
X4
X5
-
3+
-
4+
PE
24 V
0 V
-
1+
-
2+
+
U
-
+
U
-
+
U
-
+
U
-