Appendix
A.1 Technical data
A.1.6 Approvals and declarations
The following specifications apply to all XH-303 units.
Approvals and declarations
CE
XH-303 units comply with all applicable European Union (EU) Directives and feature the
CE marking.
Applied standards and directives
EMC (relevant for CE)
2004/108/EEC 2014/30/EU
IEC/EN 61000-6-2
Interference immunity for industrial environments
IEC/EN 61000-6-3
Emitted interference for residential areas
Security
DIN EN 60529
Degrees of protection provided by enclosures
Mechanical
shock res-
istance
IEC/EN 60068-2-27
15g /11ms
Vibration
IEC/EN 60068-2-6
Displacement amplitude: 5–9 Hz: 3.5 mm; 9–60 Hz: 0.15
mm
Acceleration amplitude: 60–150 Hz: 2 g
Free fall, pack-
aged
IEC/EN 60068-2-31
RoHS
Directive 2011/65/EC
conform
Ambient climatic conditions
Air pressure (in operation)
795 - 1080 hPa
Max. 2000 m above sea level
Temperature
Operation
ϑ: ± 0 – +50 °C (+32 – +122 °F)
Mounting position
α
α
XH-303-70-A10-A00-2B, XH-303-10-A10-A00-2B
α ≦ ± 45°, T ≦ 50 °C (122 °F)
XH-303-15-A10-A00-2B
α ≦ ± 10°, T ≦ 50 °C (122 °F)
α ≦ ± 45°, T ≦ 45 °C (113 °F)
Inclination from vertical:
⍺
≦ ± 45° at operating temperature ≦
45°C (113°F) possible (if using natural convection)
Storage / Transport
ϑ: -20 – + 60 °C (-4 – +140 °F)
Humidity
Relative humidity 10 - 95 %
Condensation
Non-condensing
XH-303
09/22 MN048029EN Eaton.com
89