3. Installation
3.3 Mounting
3.3 Mounting
NOTICE
Arrange for a professional technician to mount the device.
CAUTION
INSTALLATION CUT-OUT
The mounting cutout must be located in a position that will not defeat
the purpose of stabilizing webs or other reinforcing elements in the
control panel. If necessary, reinforcing elements must be installed/ad-
ded.
An IP65 degree of protection will only be ensured if there is sufficient
stiffness, the device is properly mounted using the original fixing
material and the gasket has a proper seat
l
Minimum sheet thickness of control cabinet where the device will
be flush mounted:
2 mm (0.08") ≦ d ≦ 5 mm (0.2")
3.3.1 Fixing and sealing
Make sure to check that the Installation are being met.→ Page 31
Make sure that the mounting cutout has the right size.
Check the gasket for damage and make sure it is resting correctly inside the
enclosure groove.
Missing parts or damage
If you notice anything wrong, please contact your distributor or
Eaton Service
Contact info.
Service page: