46
Electrical System Interface
Eaton PBSC Installation Requirements
•
Wiring for HIL (TCM J1-27 and J1-28 to PBSC C2-F2 and C2-F1) shall meet Network Communications Requirements in
this section.
•
Electrical connections for PBSC interface shall conform to intent in Section 5 - Typical System Wiring with Eaton PBSC.
Note:
See “Dimmer Control Input Requirements for PBSC and Eaton Shift Lever” in this section for additional
requirements
.
Typical System with Eaton PBSC
From To
Description
J1-27
C2-F2
HIL LOW (Proprietary CAN)
J1-28
C2-F1
HIL HIGH (Proprietary CAN)
J1-25
C2-J3
Shift Control Power Minus
J1-31
C2-C1
Shift Control Power Plus
C2-B3
Dimmer Control Input
27
28
25
31
31
24
25
29
30
15
16
26
20
34
27
28
32
33
18
19
7
3
8
9
1
2
6
11
12
4
5
22
21
38
36
37
13
14
35
10
17
23
F
r
o
n
t View
TCM Co
nn
ecto
r
(Vehicle I
n
te
r
face)
Dimme
r
co
n
t
r
ol i
n
p
u
t
P
us
h B
u
tto
n
S
hift Co
n
t
r
ol
P
us
h B
u
tto
n
Co
n
t
r
ol
30-way co
nn
ecto
r
C2
F 2 F 1 J 3 C 1 B 3
B
u
lkhead co
nn
ecto
r
located at fi
r
ewall
A1
A2
A3
B1
B3
C3
D1
D2
D3
E1
E2
E3
F3
H1
H2
H3
F
r
o
n
t View
PB
S
C (30-Way Co
nn
ecto
r
)
B2
C2
K3
J1
K1
K2
G1
G2
G3
J2
C1
J3
F2
F1
Summary of Contents for UltraShift PLUS EO-11E406B-PV