SVX9000 Drives

 

    MN04003009E—November 2011    www.eaton.com

STEP 1

Keypa

d

 Operation Overview

Keypa

d

 an

d

 Display

LCD Status In

d

icators 

LED Status In

d

icators 

In

d

icator

Description

Run

Indicates that the SVX9000 is running and controlling the load. Blinks 
when a stop command has been given but the SVX9000 is still 
ramping down.

Counterclockwise Operation

The output phase rotation is BAC, corresponding to counterclockwise 
rotation of most motors.

Clockwise Operation

The output phase rotation is ABC, corresponding to clockwise rotation 
of most motors.

Stop

Indicates that the SVX9000 is stopped and not controlling the load.

Rea

d

y

Indicates that the SVX9000 is ready to be started.

Alarm

Indicates that there is one or more active drive alarm(s).

Fault

Indicates that there is one or more active drive fault(s).

I/O Terminal

Indicates that the I/O terminals have been chosen for control. 

Keypa

d

Indicates that the keypad has been chosen for control.

Bus/Communications

Indicates that the communications bus control has been chosen for 
control.

In

d

icator

Description

local

Local — Stea

d

y Illumination

Indicates that the SVX9000 is ready to be started and operated from 
the Local mode.

Local — Flashing

Indicates that the SVX9000 is ready for operating command to select 
Local or Remote operation.

remote

Remote

Indicates that the SVX9000 is operating and controlling the load 
remotely.

Remote — Flashing

Indicates that the SVX9000 is ready for operating command to select 
Local or Remote operation.

fault

Fault

Indicates that there is one or more active drive fault(s).

 

MN04003009E.fm  Page 1  Wednesday, November 9, 2011  8:47 AM

Summary of Contents for SVX9000 Series

Page 1: ...2011 Supersedes December 2003 CONTENT STEP 1 Keypad Operation Overview STEP 2 Standard Wiring Diagrams and Connections STEP 3 Start Up Wizard STEP 4 Operating and Programming Menu Navigation STEP 5 F...

Page 2: ...d Alarm Indicates that there is one or more active drive alarm s Fault Indicates that there is one or more active drive fault s I O Terminal Indicates that the I O terminals have been chosen for contr...

Page 3: ...from the keypad which is always active unless disabled by the StopButtonActive parameter used to reset the active faults Reset Resets the active faults Local Remote Switches between LOCAL and REMOTE c...

Page 4: ...is running Stop the drive to edit these parameters See the SVX9000 Application Manual for identification of these parameters specific to your chosen application Main Menu The data on the control keyp...

Page 5: ...4 STEP 2 Continued SVX9000 Power and Motor Wiring for Large Horsepower Drives 20 250 hp B M 3 L1 L2 L3 L1 L2 L3 B R External RFI Filter Optional BR Optional External Filter Optional BR Power Board 230...

Page 6: ...open no fault Contact closed fault 11 CMA Common for DIN1 DIN3 Connect to GND or 24V 12 24V Control voltage output Voltage for switches see 6 13 GND I O ground Ground for reference and controls 14 DIN...

Page 7: ...0 Hz Motor NP Speed 1720 rpm Motor NP Current 2 20 A Power Factor 0 85 Loc Ctrl Place Keypad Input Phase Supv Fault Coast Repeat Setup No Yes Rem Ctrl Place I O Terminal Local Reference Keypad Remote...

Page 8: ...Hz V7 2 Frequency Reference 0 00 Hz G1 x G6 1 Slot A Board G6 5 Slot E Board O1 Output Frequency 0 0 Hz O2 Freq Reference 0 0 Hz Ox M7 1x Multimonitor Menu Navigation Up Arrow The up arrow advances t...

Page 9: ...r menus depress the ENTER button for 2 seconds While in the other menus if there is no keypad activity the display will return to the Operate Menu after 30 seconds Code Signal Name Unit Description O...

Page 10: ...0 111 Check the rating plate of the motor P1 1 8 Nominal speed of the motor 300 20 000 rpm 1720 112 The default applies for a 4 pole motor and a nominal size frequency converter P1 1 9 Nominal current...

Page 11: ...4 20mA P1 2 4 Reference scaling minimum value 0 00 Par 1 2 5 Hz 0 00 303 Selects the frequency that corresponds to the min reference signal 0 00 No scaling P1 2 5 Reference scaling maximum value 0 00...

Page 12: ...ctive 13 OP freq limit 1 superv 14 Remote Control Active 15 Thermistor fault warng 16 Fieldbus input data P1 3 8 Relay output 1 function 0 16 2 313 Same as parameter 1 3 7 P1 3 9 Relay output 2 functi...

Page 13: ...running no testing P1 4 6 Start function 0 1 0 505 0 Ramp 1 Flying start P1 4 7 Stop function 0 3 1 506 0 Coasting 1 Ramp 2 Ramp Run enable coast 3 Coast Run enable ramp P1 4 8 DC braking current 0 00...

Page 14: ...00 100 00 603 n x Unmot P1 6 6 V Hz curve midpoint frequency 0 00 Par 1 6 4 Hz 60 00 604 P1 6 7 V Hz curve midpoint voltage 0 00 100 00 100 00 605 n x Unmot Parameter max value par 2 6 5 P1 6 8 Output...

Page 15: ...constant 1 200 min 45 707 P1 7 12 Motor duty cycle 0 100 100 708 P1 7 13 Stall protection 0 3 0 709 0 No response 1 Warning 2 Fault stop acc to 1 4 7 3 Fault stop by coasting P1 7 14 Stall current 0...

Page 16: ...00 s 30 00 718 P1 8 3 Start function 0 2 0 719 0 Ramp 1 Flying start 2 According to par 1 4 6 P1 8 4 Number of tries after undervoltage trip 0 10 0 720 P1 8 5 Number of tries after overvoltage trip 0...

Page 17: ...ult 44 Device change different type 7 Saturation trip 26 Startup prevented 45 Device added different type 8 System fault 29 Thermistor fault 50 Analog input Iin 4 mA for the signal range 4 to 20 mA 9...

Page 18: ...e new item Press the ENTER key to accept the change Code Signal Name Unit Description V7 1 Output Frequency Hz Output frequency V7 2 Frequency reference Hz Frequency reference setting V7 3 Motor speed...

Page 19: ......

Page 20: ...d to ensuring that reliable efficient and safe power is available when it s needed most With unparalleled knowledge of electrical power management across industries experts at Eaton deliver customized...

Reviews: