![Eaton Scantronic i-on10 Configuration Manual Download Page 63](http://html1.mh-extra.com/html/eaton/scantronic-i-on10/scantronic-i-on10_configuration-manual_3911046063.webp)
Test Menu
Page 63
Signal Strengths
Radio Keypads
KEY-RKPZ
This option allows you check the received signal strength from KEY-RKPZ radio
keypads belonging to the system.
The display shows first: the strength of the most recent signal it has received from the
keypad, and second: (in brackets) the minimum strength signal it has received from
the keypadsince the records were last reset. The control unit is always recording
signal strengths, whether or not you are using the Signal Strength menu.
A minimum reading of 2 is acceptable. (When reading from the web interface or other
software, a minimum reading of 4 is needed if the control unit is in User mode, or 2 if
it is in Installer mode.)
To reset the signal strength records press “D” while you are in the
Tests
– Signal
Strengths
menu. When you press “D”, the control unit resets the signal strength
records for ALL radio keypads.
You can also reset the signal strength record of an individual radio keypad. To do this
press “#” while the display shows the signal strength of the radio keypad you wish to
reset.
Outputs
Select the
Wired Outputs
or
Plug-by Outputs
, then
or
to select the output you wish to
test, followed by
to activate the output. Press
again to deactivate the output. Press
to finish the test.
Note:
If you have programmed a plug-by output as an ATS Test output, then when you
test that output, the control unit will pulse the output active for the correct length of time to
start a call in any connected dual-signalling communicator. You do not need to deactivate
the output (This test is compliant with Form 175).
When you complete testing the outputs, check that they are in the state you wish to leave
them in.
Prox Tags
This allows you to test a user’s proximity tag.
The keypad display shows a message asking you to present the tag to the keypad.
Hold the proximity tag up to the sensor on the keypad.
The keypad display shows the user number and name of the proximity tag owner.
Locate Bus Device
This option allows you to list all the keypads connected to the bus, and to find out where
they are located by activating their internal sounders.
Select the keypad to locate, then press
to turn on the keypad's sounder (press
or
to turn it off again). You can also silence the sound by opening the case of the device
(activating the tamper switch).