Chapter 6: Setting Options Menu
The
Setting Options
menu contains all the options to program entry, exit and alarm
response. You can configure different settings for the full-set level and each part-set B/C/D
level.
Note:
The default settings for these options are compliant with EN50131. Changes to
some of the defaults may render the system non-compliant.
Full Set and Part Set options
Name
Use this option to name the full set or part set.
The
full-set name is displayed only in SecureConect when full-setting.
Part Set B/C/D names are displayed in the setting procedure (when selecting a part
set to set), and while the system is counting down during a timed set.
Exit Mode
Timed Set
Use this setting to make the system set after a delay. Use
Exit Time
(see page 46) to
specify the delay. The control unit logs the start of timed exit.
Note:
This option does not comply with BS8243:2010.
Final Door Set
Use this setting to complete the setting of the system by closing a door fitted with a
Final Exit zone detector. Once the door closes, the system sets after the
Settle Time
expires. Note that the exit time does not expire in this option.
The control unit logs the start of final door exit.
Note:
To enable part setting, include a zone of type Final Exit as one of the part-set
zones. Also select Final Exit in Pt.set Final Exit (see page 46).
Instant Set
The system sets immediately and without any setting tone. Keypads and
loudspeakers (if used), give a confirmation tone when the system is set or unset.
Keypads and loudspeakers give the entry tone.
Note:
This option does not comply with BS8243:2010.
Silent Set
The system sets after the time programmed in the Entry/Exit Time menu but does not
give any exit or setting tones over keypads or any loudspeaker.
Keypads and loudspeakers give the entry tone.
When the system unsets, keypads (but not loudspeakers) give a double-beep
confirmation tone.
Note:
This option does not comply with BS8243:2010.