177
Eaton RF-System
© 2015 Eaton Electrical Group
Production (Channel A, B) that can be used in an Energy
function or simply be displayed in
the SHC. The counter constant
(impulses per measured unit)
can be defined in column 'Extra
1' and the unit can be defined in
'Extra 2'.
Electric
Main
Consumpti
on
Impulse input
(Channel A, B)
The value of an Electric
consumer that already includes
sub consumers (e.g. a main
Energy meter). Will be ignored in
the statistic for Top-Consumer/-
Producer of a Zone. Can be
used in an Energy function or
simply be displayed in the SHC.
The counter constant (impulses
per measured unit) can be
defined in column 'Extra 1' and
the unit can be defined in 'Extra
2'.
Electric
Main
Production
Impulse input
(Channel A, B)
The value of an Electric producer
that already includes sub
producers (e.g. a main Energy
meter). Will be ignored in the
statistic for Top-Consumer/-
Producer of a Zone. Can be
used in an Energy function or
simply be displayed in the SHC.
The counter constant (impulses
per measured unit) can be
defined in column 'Extra 1' and
the unit can be defined in 'Extra
2'.
Extra options for devices:
As explained in the possible functions for the different device channels there are several different
extra options available depending on the device type.
Extra
option
available for Explanation
Contact
type
all binary
inputs
Possibility to define the contact
type of the connected device
channel. Options: Break contact,
Make contact (default)
ON-State
all binary
inputs
Possibility to define a user specific
state for ON (max. 10 characters)
that will be display in the GUI of
the Smart Home Controller.
OFF-State all binary
inputs
Possibility to define a user specific
state for OFF (max. 10 characters)
that will be display in the GUI of
the Smart Home Controller.
Counter
constant
only Impulse
input
Possibility to define a Counter
constant in the format 'Impulses
per measured unit'
Summary of Contents for RF System 2.42
Page 1: ...Eaton RF System 2 42 Manual...
Page 123: ...123 Eaton RF System 2015 Eaton Electrical Group State Syntax of RM to user...
Page 193: ...193 Eaton RF System 2015 Eaton Electrical Group...
Page 200: ...200 Eaton RF System Help 2015 Eaton Electrical Group 7 And assign the function Blinking to it...
Page 223: ...223 Eaton RF System 2015 Eaton Electrical Group Group settings analogue actuator...
Page 224: ...224 Eaton RF System Help 2015 Eaton Electrical Group Group settings heating actuator...
Page 225: ...225 Eaton RF System 2015 Eaton Electrical Group Group settings binary input battery supplied...
Page 227: ...227 Eaton RF System 2015 Eaton Electrical Group Group settings Temperature input...