background image

 

www.omnexcontrols.com

 

call toll free: 1-800-663-8806

 

DM-R260-0003A   Revision 3

 

Reimer 

Volumetric Mixer III 

Installation / Configuration Manual 

#74-1833 Coast Meridian Road, Port Coquitlam, BC, Canada • V3C 6G5  

Ph# (604) 944-9247 • Fax# (604) 944-9267 

Toll Free 1-800-663-8806 

DM-R260-0003A 

June 5, 2015 

Version 3 

T110c Transmitter 

R260 Receiver 

OMNEX is now 
Eaton. 

Same great 
products plus 
even more. 

Summary of Contents for Reimer Volumetric Mixer III

Page 1: ...metric Mixer III Installation Configuration Manual 74 1833 Coast Meridian Road Port Coquitlam BC Canada V3C 6G5 Ph 604 944 9247 Fax 604 944 9267 Toll Free 1 800 663 8806 DM R260 0003A June 5 2015 Version 3 T110c Transmitter R260 Receiver OMNEX is now Eaton Same great products plus even more ...

Page 2: ...2 www omnexcontrols com call toll free 1 800 663 8806 DM R260 0003A Revision 3 ...

Page 3: ...rious personal injury Installation PROVIDE A SAFETY CUTOFF SWITCH If maintenance is required the radio must be disconnected from power USE PROPER WIRING Loose or frayed wires can cause system failure intermittent operation machine damage etc DO NOT INSTALL IN HOT AREAS This apparatus can be damaged by heat in excess of 158 F 70 C Personal Safety MAKE SURE MACHINERY AND SURROUNDING AREA IS CLEAR BE...

Page 4: ...ommonly affects licensed radios The R260 receiver is designed to be powered from a 12VDC or 24VDC system It features 19 solid state high side driv er input output controls and a reliable E Stop control The T110C comes with 4 to 10 buttons to provide the user flexibility to control the functions they need The transmitter uses regular alkaline AA batteries and is also CCready When used with the CCDO...

Page 5: ... be connected to a current limiting fused source R260 Receiver Internal Wiring Wire Colors Yellow Dark Green Orange Green Red Green White Red Blue Red Orange Black Orange Red White Red Black Red Black White Green Green Black White White Orange Red White Green Black Black White Blue Black Blue White White Black Black Red Black White Red Red Black B7 B8 A7 A8 A9 A11 A10 A12 B1 B2 B3 B4 B5 B6 B9 A4 A...

Page 6: ...n state Make sure that wire of sufficient gauge and insulator type is used when connecting the outputs of the receiver to the con trol panel Observe any component manufacturer s instructions and recommendations for proper integration of their prod uct This includes the power ratings and requirements of such components as relays valves solenoids etc Be sure to test each of the outputs with a multi ...

Page 7: ... or leak causing injury Replace all batteries at the same time as a complete set and do not mix and match battery types NOTE Prior to inserting the batteries into the remote apply grease provided packet Dow Corning 111 Valve Lubricant Sealant to the battery contacts Due to the harsh condi tions these remotes operate in and the long term use of the rechargeable batteries the grease protects the bat...

Page 8: ...is defined in the R260 as shown in Table 1 When the R260 is power cycled the J1939 NAME is output NOTE The R260 will not transmit CAN messages unless a transmi er has been associated to the R260 receiver See Associate a Transmi er to teach the R260 to use a specific transmi er J1939 Data Frame Structure Name Field Arbitrary Address Capable Industry Group Vehicle Systems Instance Vehicle System Res...

Page 9: ... 0 Not Linked 1 Linked 0 to 1 2 1 32 Link ID Connection ID Matches ID label located inside T110c battery com partment 0 to 4294967296 6 1 8 Tx Type Transmitter Type ID 0 Unknown 3 T110 4 T150 5 T300 16 Raptor 0 to 255 7 1 8 Tx SubType Transmitter SubType ID 0 to 255 8 1 8 N A Reserved N A 65280 0xFF00 PGN 65280 0xFF00 Device ID 0x71 factory default Data Length 8 Bytes ID Format 29 Bit Period 50ms ...

Page 10: ...xFF01 1 1 1 Func on 1 0 not active OFF 1 active ON 1 2 1 Func on 2 1 3 1 Func on 3 1 4 1 Func on 4 1 5 1 Func on 5 1 6 1 Func on 6 1 7 1 Func on 7 1 8 1 Func on 8 2 1 1 Func on 9 2 2 1 Func on 10 2 3 54 N A Reserved N A 0 to 1 PGN 65281 0xFF01 Device ID 0x71 factory default Data Length 8 Bytes ID Format 29 Bit Period 50ms Priority 3 Note All data in decimal Table 2b PGN 65281 ...

Page 11: ...RT GND SHORT LINK RADIO FAULT OPERATE OPERATE E STOP STATUS I O E STOP CAN1 CAN2 Light Legend Solid Slow Flash Fast Flash Red Light Green Light Alternating Red Green Light Yellow Light A Supply power to the re ceiver The E Stop light and the Link light will come on RED and the Status light will come on GREEN 2 Power R260 A S N P N STATUS I O E STOP CAN1 CAN2 STATUS I O E STOP CAN 1 CAN 2 STATUS LO...

Page 12: ... LINK RADIO FAULT OPERATE OPERATE E STOP P N R260 S N STATUS I O E STOP CAN1 CAN2 STATUS I O E STOP CAN 1 CAN 2 STATUS LO BATT FAULT FUNCTION ON BATT SHORT GND SHORT LINK RADIO FAULT OPERATE OPERATE E STOP STATUS I O E STOP C D P N R260 S N STATUS I O E STOP CAN1 CAN2 STATUS I O E STOP CAN 1 CAN 2 STATUS LO BATT FAULT FUNCTION ON BATT SHORT GND SHORT LINK RADIO FAULT OPERATE OPERATE E STOP STATUS ...

Page 13: ... the receiver NOTE When downloading a new ID to a receiver a safety feature requires that the transmitter be in close proximity to the receiver This will prevent a transmitter from accidentally reprogramming a different receiver in the area Light Legend Solid Slow Flash Fast Flash Red Light Green Light Alternating Red Green Light Yellow Light S N P N STATUS I O E STOP CAN1 CAN2 STATUS I O E STOP C...

Page 14: ...turn transmit ter off and turn it back on again Change or Recharge Batteries Note Low batteries will last approximately 8 hours once the Low Battery light begins to flash Send the unit in for service Toggle the buttons a few times Call for service Send the unit in for service Toggle the buttons a few times Call for service Send the unit in for service To take it out of Configuration mode turn tran...

Page 15: ...erial number Transmitter is ON or OFF The voltage is greater than 32 volts Verify the battery supply voltage is between 8 to 32 volts Transmitter is ON A short to ground or excessive current draw on an output Likely caused by a wiring fault Ensure transmitter is functioning properly check status of each out put connection Press each function button and observe Fault Light If GREEN everything is OK...

Page 16: ... pressed Go to Chart 2 to test the transmitter If the transmitter is functioning correctly proceed to check the status of each of the output connections Press each of the function buttons and observe the I O Light turns GREEN everything is OK turns RED there is a short in that connection Troubleshooting Guide Chart 1 Receiver lights Status GREEN I O OFF GREEN E Stop RED Receiver OK Note If there i...

Page 17: ...tuck button 1 Toggle the buttons a few times 2 If condition persists send the unit in for service Complete in order the following steps 1 Check battery orientation 2 Clean battery contacts 3 Check Recharge or Replace batteries 4 Send in for service Troubleshooting Guide continued Chart 2 The transmitter may be in secure mode this will only be the case if the transmitter has been programmed for the...

Page 18: ... time if the original receiver unit is still on the job site Therefore it must be certain that the transmitter receiver pair are the correct set Secondly once the download procedure is completed ensure all other units on the job site are stopped Test the operation of the newly configured set to ensure no other machines on the site work with the same transmitter Once you are certain that the transm...

Page 19: ... the problem send both the transmitter and receiver in for service Note you could try to determine whether the fault lies with the transmitter or receiver by completing the Reprogram ming procedure with a different transmitter If this step works then the fault lies with the original transmitter If not the fault may lie with the receiver Caution Note Before attempting reprogramming with another tra...

Page 20: ... the Eaton products are free from defects in materials and workmanship under normal use and service for a period of ONE YEAR parts EXCLUDING SWITCHES CRYSTALS OR PARTS SUBJECT TO UNAUTHORIZED REPAIR OR MODIFICATION and labor from the date of delivery as evidenced by a copy of the receipt Eaton s entire liability and your exclusive remedy shall be at Eaton s option either the a repair or b replacem...

Reviews: