2 Engineering
2.12 Motor and Application
68
Rapid Link 5 · RAMO5 · RASP5
10/19 MN034004EN
www.eaton.com
As shown in Figure 33, the FWD rotating field direction will be disabled in
manual mode when the interlocked manual operation is activated after a
rising edge (on I1, for example) or during a continuous signal. The motor can
then only be operated in automatic mode on the RAMO5-W, or in the oppo-
site direction in manual mode on the RASP5.
Rotating field direction FWD in manual mode is possible again only after a
falling edge is registered at I1 or after a changeover to automatic mode and
back again). This also applies for sensor input I2 and rotating field direction
REV.
For RAMO5-D… and depending on parameter P1-13, the interlocked manual
mode is exclusively edge-controlled. This allows continued manual operation
in the same direction after a break point is reached by simply briefly switch-
ing over to Automatic and back again.
LED-signal under interlocked manual operation of RAMO5-W and RASP5:
•
LED
FWD
or
REV
is lit when the associated operating direction is
selected with the selector switch.
•
LED
FWD
or
REV
flashes while the selector switch is operated but
RAMO5-W or RASP5 is switched off through interlocked manual opera-
tion. (For an example of interlocked manual operation with RASP5 ).
Summary of Contents for Rapid Link RAMO5
Page 1: ...Manual Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN ...
Page 4: ...II ...
Page 10: ...6 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 122: ...4 Operation 4 3 Manual control 118 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 158: ...8 PC tool 8 2 Parameter Editor 154 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 208: ...11 Communications 11 5 OP Bus 204 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...