6 RASP5 Speed controller
6.7 Configure special settings
144
Rapid Link 5 · RAMO5 · RASP5
10/19 MN034004EN
www.eaton.com
6.7.2 Motor cable monitoring
The monitoring is carried out via parameter P2-27.
Parameter P2-27 is set to the value 1 in the factory setting.
In position 0, the fault message of the thermistor and motor cable monitoring
is deactivated.
6.7.2.1 Sensor inputs
Sensor inputs I1 and I4 are laid out for rising-edge input signals (N/O, fail-
safe). Parameters P3-06 to P3-09 are set to 0 (= OFF) in the factory setting.
When using sensors (normally closed) that switch to zero, the parameters
must be set to 1 (= ON). The signal is then inverted.
Figure 96: Configuring the sensors inputs I1 and I2#
Four sensors are currently available:
I1 - I4
->
1
I1 - I4
->
0
Parameter
Designation
Description
Unit
Min
Max
DS
P3-06
DI1 Logic
0 = close
1 = open
Note:
Change only after POWER ON/OFF active
–
0
1
0
P3-07
DI2 Logic
0 = close
1 = open
Note:
Change only after POWER ON/OFF active
–
0
1
0
P3-08
DI3 Logic
0 = close
1 = open
Note:
Change only after POWER ON/OFF active
–
0
1
0
P3-09
DI4 Logic
0 = close
1 = open
Note:
Change only after POWER ON/OFF active
–
0
1
0
→
Sensors I3 and I4 require a Y connector of type RA-XM12-Y.
Summary of Contents for Rapid Link RAMO5
Page 1: ...Manual Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN ...
Page 4: ...II ...
Page 10: ...6 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 122: ...4 Operation 4 3 Manual control 118 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 158: ...8 PC tool 8 2 Parameter Editor 154 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Page 208: ...11 Communications 11 5 OP Bus 204 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...