3 Installation
3.6 Installing the fieldbus connection
DX-NET-DEVICENET
02/14 MN04012005ZEN
www.eaton.com
21
3.6 Installing the fieldbus connection
To connect the variable frequency drive to the DX-NET-DEVICENET field bus
module, you will need a 5-pin DeviceNet plug with an appropriate
prefabricated DeviceNet cable.
3.6.1 Pin assignment
Table 4: DeviceNet pin assignment
In order to ensure that all DeviceNet field bus communications will work
properly, all the plug pins need to be connected. This applies to the 24-V bus
voltage as well. If there is no bus voltage present, the DX-NET-DEVICENET
module will be unable to communicate. In this case, the network status LED
will be in the OFF mode.
→
DeviceNet plugs and DeviceNet cables are specified by ODVA.
Make sure to only use cables specifically approved for use with
DeviceNet!
The type of cable has an influence on the maximum available
length of the bus line and thus also on the Baud rate
(
Table 5).