Menvier30
Page 37
5. Technical Specification
General
Product name
Menvier30.
Product
Description
30 zone hybrid endstation with
remote keypads.
Manufacturer
Eaton’s Security Business.
Environmental
Class II.
Operating
temperature
Tested -10 to +55°C.
Humidity
0 to 93% RH, non-condensing.
Case material
Steel.
Dimensions:
Control unit
320 x 400 x 98, mm HxWxD.
i-KP01
115 x 156 x 30, mm HxWxD
KEY-
K01/KP01/KPZ01
128 x 128 x 29, mm HxWxD
EXP-W10, EXP-
WCC, EXP-R10,
EXP-R30
230 x 144 x 44, mm HxWxD
Weight:
Control unit
4.9 kg (without stand-by
battery).
i-KP01
0.26 kg
KEY-K01
0.19 kg
KEY-KP01
0.19 kg
KEY-KPZ01
0.19 kg
EXP-W10,
EXP-WCC,
EXP-R10, EXP-
R30
0.42 kg
0.43 kg
0.39 kg
0.39 kg
Capacities
Zones
10 onboard (FSL) or 2 wire CC.
30 max (with expanders)
Outputs
12 plug-by communicator
outputs on control unit, plus
30 max for the rest of the
system.
(Note: each EXP-R10 provides 8
radio outputs.)
Expanders and
Wired Keypads
10 max devices (see note 1)
Radio Keypads
4 max (two per radio expander)
External Radio
Sirens
4 max (two per radio expander)
WAMs
1 max (repeater mode only)
Loudspeakers
1 on control unit, 1 per expander
Plug on
communication
modules
One
Other ports
1 x USB
Wards
4 (see note 2)
Shunt Groups
1
Log capacity
Up to 350 events: 250
mandatory events, 100 non-
mandatory. Stored in EEPROM
memory, available for at least 10
years without power.
Internal Clock
±10 minutes over one year
(depending on the accuracy of
the mains supply frequency).
User Codes
50 (plus installer code)
Remote controls
50 (one per user)
HUA Alarms
50 (one per user)
Proximity tags
50 (one per user)
Notes:
1. Wired keypads, wired zone expanders, and
radio zone expanders are all bus devices. You
can connect any combination of these devices
to the bus.
2. The system can be used as EITHER a ward
based system OR a part setting system. When
used as a part setting system there are four
setting levels available: Full Set and Part Sets
B, C and D.
Security
Security Grade
Grade 2
Radio detector
differs
16,777,214 (2
24
-2).
Radio
Supervision
Programmable.
Number of
access codes
50 plus one installer
Access code
differs
10,000 differs with 4 digit
codes.
All digits may be any number 0
to 9.
Code blocking
Blocked for 90s after four
incorrect codes in series.
Proximity tag
differs
4,294,967,296 (2
32
)
Power Supply
This product complies with the requirements of EN50131-6
Type A power supply at Grade 2 and environmental class II.
Power supply type
A
Mains power supply
requirements
10%/-15%,
200mA max, 50Hz.
Total power supply
capacity:
1.0A
(of which 250mA is used
for battery recharge and
750mA is available for
powering the system).
12V Aux supply*:
550mA max
12V Bell supply*
550mA max
Comms power
supply*:
400mA max
12V Expander Bus*:
400mA max
LS connectors
280mA in alarm.
*Note: The ratings given here represent the
maximum current that can be drawn before
triggering over-current protection.