5. Technical Specification 

General 

Product name 

Menvier30. 

Product 
Description 

30 zone hybrid endstation with 
remote keypads. 

Manufacturer 

Eaton’s Security Business.  

Environmental 

Class II.  

Operating 
temperature 

Tested -10 to +55°C. 

Humidity 

0 to 93% RH, non-condensing. 

Case material 

Steel. 

Dimensions:

 

 

Control unit 

320 x 400 x 98, mm HxWxD. 

i-KP01 

115 x 156 x 30, mm HxWxD 

KEY-
K01/KP01/KPZ01 

128 x 128 x 29, mm HxWxD 

EXP-W10, EXP-
WCC, EXP-R10, 
EXP-R30 

230 x 144 x 44, mm HxWxD 

Weight:

 

 

Control unit 

4.9 kg (without stand-by 
battery). 

i-KP01 

0.26 kg 

KEY-K01 

0.19 kg 

KEY-KP01 

0.19 kg 

KEY-KPZ01 

0.19 kg 

EXP-W10, 
EXP-WCC, 
EXP-R10, EXP-
R30 

0.42 kg 
0.43 kg 
0.39 kg 
0.39 kg 

Capacities 

Zones 

10 onboard (FSL) or 2 wire CC. 
30 max (with expanders) 

Outputs 

12 plug-by communicator 
outputs on control unit, plus  
30 max for the rest of the 
system. 
(Note: each EXP-R10 provides 8 
radio outputs.) 

Expanders and 
Wired Keypads 

10 max devices (see note 1) 

Radio Keypads 

4 max (two per radio expander) 

External Radio 
Sirens 

4 max (two per radio expander) 

WAMs 

1 max (repeater mode only) 

Loudspeakers 

1 on control unit, 1 per expander 

Plug on 
communication 
modules 

One 

Other ports 

1 x USB 

Wards 

4 (see note 2) 

Shunt Groups 

Log capacity 
 

Up to 350 events: 250 
mandatory events, 100 non-
mandatory. Stored in EEPROM 
memory, available for at least 10 
years without power.  

Internal Clock 

±10 minutes over one year 
(depending on the accuracy of 
the mains supply frequency). 

User Codes 

50 (plus installer code) 

Remote controls 

50 (one per user) 

HUA Alarms 

50 (one per user) 

Proximity tags 

50 (one per user) 

Notes: 
1. Wired keypads, wired zone expanders, and 
radio zone expanders are all bus devices. You 
can connect any combination of these devices 
to the bus. 
2. The system can be used as EITHER a ward 
based system OR a part setting system. When 
used as a part setting system there are four 
setting levels available: Full Set and Part Sets 
B, C and D. 

Security 

Security Grade 

Grade 2 

Radio detector 
differs 

16,777,214 (2

24

 -2). 

Radio 
Supervision 

Programmable. 

Number of 
access codes 

50 plus one installer 

Access code 
differs 

10,000 differs with 4 digit 
codes.  
All digits may be any number 0 
to 9. 

Code blocking 

Blocked for 90s after four 
incorrect codes in series.  

Proximity tag 
differs 

4,294,967,296 (2

32

Power Supply 

This product complies with the requirements of EN50131-6 
Type A power supply at Grade 2 and environmental class II.  

Power supply type 

Mains power supply 
requirements  

10%/-15%, 
200mA max, 50Hz. 

Total power supply 
capacity: 

1.0A  
(of which 250mA is used 
for battery recharge and 
750mA is available for 
powering the system). 

12V Aux supply*: 

550mA max 

12V Bell supply* 

550mA max 

Comms power 
supply*: 

400mA max 

12V Expander Bus*: 

400mA max 

LS connectors 

280mA in alarm. 

*Note: The ratings given here represent the 
maximum current that can be drawn before 
triggering over-current protection. 

Summary of Contents for MENVIER30

Page 1: ...Menvier30 Security System Installation Guide Issue 2...

Page 2: ...ing you to potential problems or hazards Each of these are marked by the words Note Caution or WARNING Note Describes conditions that may affect the proper functioning of the equipment but will not da...

Page 3: ...eakers 21 Step 5 Connect Control Unit to Mains 21 Mains Cabling 21 Step 6 Connect Wired Zones 21 Four Wire Closed Circuit Connections 21 Two Wire Closed Circuit Connections 22 Fully Supervised Loop Co...

Page 4: ...Menvier30 Page iv This page is intentionally blank...

Page 5: ...a passive infra red detector smoke detector external siren 4 button remote control and remote radio keypad This control unit is designed and approved to be used as part of a Security Grade 2 system Zo...

Page 6: ...of the Installer s programming menu please read Menvier30 40 100 300 Engineering Guide available from www coopersecurity co uk Installer Programming Interface Once fitted and powered up you can progr...

Page 7: ...metal cabinets from their original position can all affect the signal from a transmitter Please read Eaton s Security Business publication Guidance Notes for Wireless Alarm System Installations obtai...

Page 8: ...n metal or conducting films These glasses are particularly poor at transmitting radio waves Guided Tour CAUTION All printed circuit boards for the Menvier30 its expanders and keypads have been tested...

Page 9: ...g by output connectors 4 Tamper switch connector 5 ADSL filter pins 6 On board communicator connections 7 Off hook LED 8 USB socket Mini B 9 Sockets for plug on module 10 Loudspeaker Bell and Strobe c...

Page 10: ...envier30 Page 6 1 Built in communicator telephone line connector 2 Siren and strobe 3 Loudspeaker 4 Bus cable connector 5 Output transistorised 6 Aux power 7 Wired zone connectors Figure 4 Control Uni...

Page 11: ...To open the keypad first gently prise off the trim on the front and remove the two screws Next carefully lever the front of the keypad containing the PCB and display away from the keypad rear housing...

Page 12: ...push the bottom edge of the caps in with the end of a small screwdriver to start them Remove the two screws hidden underneath see Figure 9 Gently swing the lower side of the front out from the back bo...

Page 13: ...r KEY EP Terminals for zones 4 Sounder volume control 5 Connector for data bus and output terminal 6 Jumpers for addressing and LED function 6a Addressing not used 6b LED functions and RS485 bus termi...

Page 14: ...ker connectors 19 Outputs Figure 15 EXP W10 Wired Expander 1 Cable entry also behind PCB 2 Central keyhole 3 PCB 4 Relay card i rc01 connector 5 Aux power 6 Link to enable disable front rear tamper sw...

Page 15: ...able front rear tamper switch 6 Lid tamper rear tamper behind PCB 7 Bus termination jumper 8 Addressing button 9 Fixing holes 10 Engineering keypad connector 11 Bus cable connector 12 Sounder 13 Louds...

Page 16: ...example system and would meet the Grade 2 requirements Note All current drawn from the Aux terminals 12V must be included in the overall calculation CAUTION Ensure that the system does not demand more...

Page 17: ...ain see Fig 18 In a star configuration If there are only two arms on the star then this is the same as a daisy chain configuration see Daisy Chain 1 in Figure 18 If required fit the termination jumper...

Page 18: ...80mA 0 61V 1 22V 1 82V 2 43V 3 04V 3 65V 4 26V 4 86V 5 47V 6 08V 400mA 0 64V 1 28V 1 92V 2 56V 3 20V 3 84V 4 48V 5 12V 5 76V 6 40V Reducing Voltage Drop Method 1 Double up the supply connections 12V a...

Page 19: ...ere must be enough space around this point to fit the supplied tamper shroud see Figure 21 Fitting Plastic Feet and Tamper Sleeve The control unit is supplied from the factory with four plastic feet a...

Page 20: ...uring Screw When the PCB is in place connect the wires from the transformer to the 20Vac connector on the PCB 18 in Figure 3 Installing the Lid Back Tamper Figure 25 Lid Back Tamper Fit combined lid b...

Page 21: ...ontrol systems If you mount prox readers closer together than one meter including on the other side of walls then the two prox readers will interfere and may not work correctly Fitting Keypads Select...

Page 22: ...ng mode allows you to enable or disable the LEDs in the ABCD keys and the Navigation key It is possible to enter keypad programming mode when the keypad is not connected to a control unit but simply p...

Page 23: ...any fault reports MENU STATUS FLT LED 4 Leave local programming mode and save your changes see below To Leave Local Programming Mode and Save Changes EITHER Press OR Close the keypad tamper The keypad...

Page 24: ...gure 32 shows the wiring connections at the keypad Figure 32 Connecting the External Prox Reader Tone Volume All Keypads To alter the volume of non alarm tones from the keypad adjust the keypad sounde...

Page 25: ...tions must be carried out by a qualified electrician and must comply with the current local regulations e g IEE Mains Cabling Note To avoid mains interference the mains cable must enter the control un...

Page 26: ...r you can mimic the setting by using 4k7 2k2 4 wire CC zone wiring option and then connecting the detector to the alarm terminals and placing a short across the tamper terminals Fully Supervised Loop...

Page 27: ...igure 43 shows the connections required Figure 43 Wiring Two Detectors per Zone FSL Figure 44 shows an example of wiring double doors with two door contacts to one FSL zone Each door contact is a reed...

Page 28: ...ng Bell Tamper unnecessarily Wired Outputs on Expanders Each EXP W10 wired expander provides connections for up to four transistor driven outputs Each output has a maximum rating of 500mA but note tha...

Page 29: ...as described above Figure 49 Wiring TR from External Sounder to a Zone on the Expander Remote Loudspeakers Optional If you wish to add a 16 Ohm wired Loudspeaker unit then connect it as shown in Figur...

Page 30: ...th or without secondary proceed indication Note The built in communicator is not suitable for connection as an extension to a pay phone or to 1 1 carrier systems Approval The built in communicator is...

Page 31: ...the authorised maintainer To connect the telephone line see Figure 52 i Using a two core telephone cable strip off 5mm and feed the cable through one of the entries marked 10 in Fig 2 in the rear of...

Page 32: ...s present and 0V when the fault is absent Tell Back Input This input is designed to allow a plug by communicator to indicate to the control unit that the user can reset the system after a system tampe...

Page 33: ...that the sudden noise does not startle you and cause a fall 1 Apply mains power to the control unit The keypads and internal sounder may give an alarm tone The heartbeat LED on the control unit PCB se...

Page 34: ...s OK Two No communication over the bus in the last 10 seconds Three No bus address allocated to expander Four No poll request received from control unit in the last minute Transferring to Another Keyp...

Page 35: ...tive If you need to re enter the Installer Menu 1 Make sure the system is unset and showing the standby screen time and date 2 Key in the Installer access code The default Installer access code is 123...

Page 36: ...to display the desired wiring type on the bottom line of the display and then press to select it The system loads all defaults except for Access Codes and the Log The display briefly shows Followed b...

Page 37: ...screw NOTE It is possible for convenience to place links over tamper contacts to inhibit tamper alarm for example during installation or if the unit is installed inside a larger tampered housing Beca...

Page 38: ...ay Replies 2 Way Set Instant Duress Enable User reset Zone alarms 6 Zone tampers System tampers Confirmation Confirmation Mode Basic DD243 BS8243 Confirmation time 7 After entry 7 Entry keypad lock 7...

Page 39: ...sabled 15 Appears only when Dynamic Test Call is disabled 16 Appears only if EXP PSU is fitted 17 Appears only if Report Mode Fast Format AND Confirmation Mode Basic 18 Shows None on Menvier30 If no c...

Page 40: ...employ the Test Locate Bus Device option in the Installer Menu Use this option to make a selected bus device give a continuous tone from its sounder Once you have found the bus device you can silence...

Page 41: ...ithout power Internal Clock 10 minutes over one year depending on the accuracy of the mains supply frequency User Codes 50 plus installer code Remote controls 50 one per user HUA Alarms 50 one per use...

Page 42: ...e range 10 0 5V to 13 8V 12V Aux output voltage range 10 0 5V to 13 8V 12V Bell output voltage range 10 0 5V to 13 8V Max p to p ripple voltage 0 5V Standby Battery 12V 7Ah sealed lead acid not suppli...

Page 43: ...726rEUR 60 Short range hand held HUD Detectors 713rEUR 00 Pet tolerant PIR 714rEUR 00 PIR Transmitter Small case 720rEUR 00 Smoke Detector Transmitter 734rEUR 00 01 CC FSL Door Contact Transmitter whi...

Page 44: ...www coopersecurity co uk Product Support UK Tel 44 0 1594 541978 Available between 08 30 to 17 00 Monday to Friday Product Support Fax 01594 545401 email techsupport coopersecurity co uk Part Number 1...

Reviews: