Menvier30
Installation
Page 25
Figure 48 Wiring External Sounder to Expander
FSL wiring
. Connect
–TR to the left hand terminal
of a zone connector, see Figure 49. (The left hand
terminal is the one next to the “Z” on the terminal
label.) The maximum length of wire is 50m when
using 2k2/4k7 or 4k7/4k7 FSL wiring and a single
core of standard 6-core alarm cable. Fit EITHER a
2k2 resistor if using 2k2/4k7 FSL, OR a 4k7
resistor if using 4k7/4k7 FSL. Do not use any
other FSL resistor combinations.
CC wiring
Eaton’s Security Business does NOT
recommend that you use CC wiring for this
application. The maximum length of wire
allowable is only 6m. Instead
Eaton’s Security
Business recommends using FSL wiring, as
described above.
Figure 49 Wiring
–TR from External Sounder to a
Zone on the Expander.
Remote Loudspeakers (Optional)
If you wish to add a 16 Ohm wired Loudspeaker
unit, then connect it as shown in Figures 46 or 47.
The control unit provides connections for one
loudspeaker. Expanders provide connections for
one loudspeaker each. Do not connect another
loudspeaker in parallel. You may connect another
loudspeaker in
series
, but this will decrease the
maximum volume from the speakers.
Note: Loudspeakers are not warning devices as
described by EN50131-4. Although loudspeakers
may mimic alarm tones, they also give alert tones
and other progress tones when setting and
unsetting the alarm system.
Output on KEY-KPZ01
Figure 50 shows the wiring required to connect an
output the output terminal on the KEY-KPZ01.
Figure 50 KEY-KPZ01 Output Wiring
R
S
4
8
5
0
V
1
2
V
A
B
O
P
1K0 Ohm Resistor
LED
(Light Emitting Diode)